Friedrich PDXDEA Air Conditioner User Manual


 
Model PDXDAA & PDXDEA
PDXDAA & PDXDEA Friedrich Air Conditioning Co. Pg 5/5
Post Office Box 1540 / San Antonio, Texas 78295-1540
(210) 546-0500 / (800) 541-6645 / www.friedrich.com
Install Wall Register
20. In adjacent room center the register on the duct
end and push into the duct until the frame is
tight to the wall.
NOTE: The clips on the register are designed to
hold it in place.
Adjust Volume of Airflow Between Rooms
NOTE: The plenum is factory set for maximum
discharge of airflow from front of unit. To adjust
the airflow between 2 rooms, adjust the internal
baffle as follows:
21. Remove plenum discharge grille.
22. Remove 2 screws holding baffle. See Fig 11.
23. Position baffle, and secure for desired airflow
setting. See Table 1.
24. Replace plenum discharge grille.
The Installation of the Lateral Duct Accessory Kit is now complete.
Thank you for purchasing this Friedrich accessory.
Please contact us if you have comments or questions.
Figure 11 – Baffle Attachment Screw Locations