T
ROUBLESHOOTING
E
rror Code Cause Troubleshooting
E1
Electrical short on both temperature
sensor and PCB
Contact an electrician for repair
E2
Electrical short of temperature
sensor copper tube and PCB wiring
Contact an electrician for repair
E4
Indicates water tank full or poor
contact of signal plug.
User needs to pull out the rubber stopper
which is located at the bottom of the unit,
to drain the water away. Check that the plug
has been wired correctly.
T
ROUBLE SHOOTING
SPECIFICATION
M
odel No.
P08S
P10S
Power Source 120V~60Hz
Cooling Capacity
8000BTU/H 10000BTU/H
EER
8.3 8.4
Amps
9A 11A
Moisture Removed
63.4 Pints/Day 84.5 Pints/Day
Refrigerant
R410A, 15.9 ozs (450g) R410A
Dimensions 11 1/3” W(288mm) x 16 6/7”D (428mm) x 25 1/5”H (640mm)
(CE) N 842/2006: R410A is a kind of fluorinated greenhouse gases covered by the Kyoto Protocol.
Its total global warming potential (GWP) is 1975
T
his marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible hazards to the environment or human
health from uncontrolled waste disposal, please recycle it to prove the sustainable reuse of
material resources. Please ask return and collection systems or contact the retailer where
the product was purchased to return your used device, they can recycle products safely.
16
Cooling Power Input
964W
1190W
, 18 ozs (510g)