SLEEP TIMER OPERATION
Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.
To Use the SLEEP Timer
While the air conditioner is operating or stopped, press the
SLEEP button (Fig. 6 J).
The indoor units OPERATION Indicator Lamp (red) (Fig. 3 5) and the TIMER
Indicator Lamp (green) (Fig. 3 6) will light.
To Change the Timer Setting
Press the SLEEP button (Fig. 6 J) once again and set the
time using the SET TIME buttons (Fig. 6 L).
Set the time while the Timer Mode Display is flashing (the flashing will continue
for about five seconds).
button: Press to advance the time.
button: Press to reverse the time.
About five seconds later, the entire display will reappear.
To Cancel the Timer:
Use the TIMER button to select TIMER RE-
SET.
The air conditioner will return to normal op-
eration.
To Stop the Air Conditioner During Timer
Operation:
Press the START/STOP button.
About the SLEEP Timer
To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat setting
in accordance with the time setting. When the set time has elapsed, the air conditioner completely stops.
Set time
1 hour
2 °F
4 °F
During Cooling/Dry operation:
When the SLEEP timer is set, the thermostat setting is auto-
matically raised 2 °F every sixty minutes. When the thermo-
stat has been raised a total of 4 °F, the thermostat setting at
that time is maintained until the set time has elapsed, at
which time the air conditioner automatically turns off.
SLEEP timer setting