Friedrich CP08F10 Air Conditioner User Manual


 
Service Manual 11
Electrical Parts
1. Remove the cabinet.
2. Remove the evaporator.
3. Remove the orifice.
4. Remove the blower.
5. Remove the fan.
6. Remove the control box cover and housing of the
motor in the control box.
7. Remove the 2 screws which fasten the motor from
themountmotor.(SeeFigure7)
8. Remove the motor.
9. Re-install the components by referring to the
removalprocedure,above.(SeeFigure7)
Figure7
3. MOTOR
1. OVERLOAD PROTECTOR
1. Remove the cabinet.
2. Remove the nut which fastens the terminal cover.
3.Removetheterminalcover.(SeeFigure8)
4. Remove all the leads from the overload protector.
5. Remove the overload protector.
6. Re-install the component by referring to the
removal procedure, above.
Figure8
Disassembly
2. COMPRESSOR
1. Remove the cabinet.
2. Discharge the refrigerant system using a Freon
TM
Recovery System.
If there is no valve to attach the recovery system,
install one (such as a WATCO A-1) before venting
the Freon
TM
. Leave the valve in place after
servicing the system.
3. Remove the overload protector.
4. After purging the unit completely, unbraze the
suction and discharge tubes at the compressor
connections.
5. Remove the 3 nuts and the 3 washers which
fasten the compressor.
6.Removethecompressor.(SeeFigure9)
7. Re-install the components by referring to the
removal procedure, above.
Figure9