Friedrich CP18C30 Air Conditioner User Manual


 
4
4
Window installation
Window opening measurements:
30"min. to 40" max. (76.2 cm to 101.6 cm) opening width.
20" min. (50.8 cm) opening height.
Through-the-wall installation
The wall opening measurements should be:
Width: 30" (76.2 cm) plus twice thickness of wood used to
build fr
ame.
Hei
ght: 19ı ˇ�" (50.2 cm) plus twice thickness of wood used to
build fr
ame.
Depth: 2
ˇ�" (6.4 cm) minimum to 8" (20.3 cm) maximum.
Electrical Requirements
Ground wire must be connected to ground screw located in lower
righ
t corner of air conditioner when air conditioner is in cabinet.
Th
e electrical ratings for your air conditioner are listed on the
mod
el and serial number label. The model and serial number
label is lo
cated behind the front panel on the flange below the
control panel area.
Specific electrical r
equirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cor
d.
A. 30" min. (76.2 cm)
B. 20" min. (50.8 cm)
A.19
" (50.2 cm)
B.
26
" (66.1 cm)
C.Wood t
hickness
D.
2
" (6.4 cm) minimum to
8" (20.3 cm) maximum
A
B
B
C
C
A
D
Power supply
co
rd Wiring requirements
230-volt (207 min. - 253 max.)
0-12 a
mps
15-amp time-delay fuse or circuit breaker
Us
e on single outlet circuit only.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
��
(0.6 cm)
1
/2"
3
/4
1
/2
1
/2
3
/4
1
/2