FMI (V)UM42(SR,SI,HR,HI) Indoor Fireplace User Manual


 
www.fmiproducts.com
122274-01G12
NOTICE: If your installation does
not meet the minimum clear-
ances shown, you must do one

 -

 
BUILT-IN FIREBOX INSTALLATION
Built-in installation of this rebox involves
installing rebox into a framed-in enclosure.
This makes the front of rebox ush with wall.
If installing a mantel above the rebox, you
must follow the clearances shown in Figure
7, page 11. Follow these instructions to install
the rebox in this manner.
1. Frame in rough opening. The rebox fram-
ing should be constructed of 2 x 4 lumber
or heavier. Use dimensions and rough
opening layout in Figure 8. Adjust framing
so that rebox ushes with nished wall
surface. If installing in a corner, use dimen-
sions in Figure 9, for rough opening.
2. Install gas piping to rebox location. See
Installing Gas Line on page 14 and Con-
necting to Gas Supply in log set owner’s
manual.
3. Carefully set firebox in front of rough
opening with back of rebox inside wall
opening.
4. Carefully insert rebox into rough opening.
5. Attach rebox to wall studs using nails
or wood screws through holes in nailing
ange (see Figure 10).
6. Install and properly test gas log heater.
Follow installation instructions included
with the vent-free gas log heater that is
being installed.
IMPORTANT: When nishing your rebox,
combustible materials such as wall board,
gypsum board, sheet rock, drywall, plywood,
etc. may be butted up next to the sides and top
of the rebox. Combustible materials should
never overlap the rebox front facing.
WARNING: Do not allow any


IMPORTANT: Noncombustible materials such
as brick, tile, etc. may overlap the front fac-
ing, but should never cover any necessary
openings.
WARNING: Do not allow non-


INSTALLATION
Continued
Figure 10 - Attaching Firebox to Wall
Studs
Nailing
Flanges
Nails or
Wood
Screws
Figure 8 - Framing Dimensions
71" (50" Models)
100" (50" Models)
65" (42" Models)
92" (42" Models)
86.5" (36" Models)
61" (36" Models)
Maintain 1
1
/
2
"
Clearance at Sides
and Back of Fireplace
1
1
/
2
" Clearance
Not Required at
Nailing Flanges
Figure 9 - Corner Installation
30.125"
59.375" (50" Models)
54.625"
51.375" (42" Models)
45.375" (36" Models)
28.250"
(36" Models)