FMI (V)T32P-A Indoor Fireplace User Manual


 
www.fmiproducts.com
116646-01J 19
3. Place blower against lower rear wall of
rebox outer wrapper with exhaust port di-
rected upward and thermodisc positioned
up near fireplace bottom. Thermodisc
must be oriented near replace bottom
as shown in Figure 29, in order to sense
temperature and properly operate. Blower
will be held in position against back wall
by magnets incorporated onto blower
housing (see Figure 29).
4. Be certain that all wire terminals are
securely attached to terminals on blower
motor and thermal switch and that screw
for thermodisc bracket and green ground
wire is tight.
5. Mount speed control box against mount-
ing plate provided in lower fireplace
cavity by placing plastic control shaft
forward through round hole (see Figure
27, page 18).
6. While supporting speed control, secure
control shaft with lock nut by pushing and
turning lock nut with pliers clockwise until
it is tight against mounting plate. Place
control knob provided on shaft (see Figure
27, page 18).
FIREPLACE INSTALLATION
Continued
Thermodisc
Figure 29 - Blower Model BKT
Air Flow
Direction
Route BKT Blower
Through This Area
Magnets
Blower
Location
Side View Firebox Bottom
Black
Wire
Phillips
Screw
Blue
Wire
Ring
Terminal on
Green Wire
White
Wire
Thermal
Switch
Thermal
Switch
Bracket
Power Cord
Air Flow
Direction
Magnetic
Strips
Figure 30 - Blower Wiring Diagram for
Thermostat-Controlled Models
Blower Wiring Diagram
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and dan-
gerous operation. Verify proper
operation after servicing.
Blue
Variable
Fan Switch
Fan Switch
(N.O.)
Green
White
On
110/115
V .A.C.
Blower
Motor
Black
Off
1
2
Black
7. Check to make sure that power cord is
completely clear of blower wheel and
that there are no other foreign objects in
blower wheel. Also double check all wire
leads and make sure wire routing is not
pinched or in a precarious position. Cor-
rect accordingly.
8. Turn on power to duplex outlet if previ-
ously turned off per warning in column 2,
page 17.
9. Plug in blower power cord to duplex
outlet.
10. Blower will only run when speed control
knob is in the ON position and thermal
switch senses temperature after replace
begins to heat up. Blower speed can be
adjusted by rotating control knob. To turn
off, turn knob fully counterclockwise until
it clicks off. If blower is ON and has been
running with replace operating, blower
will continue to run for a short time after
replace has been turned off. As thermal
switch cools down, blower shuts down
automatically.
11. Peel off the backing paper and stick the
supplied wiring diagram decal on the
rebox bottom approximately 12" in front
of the blower (see Figure 28, page 18).