FMI VFP18MV Gas Heater User Manual


 
19
105071
OWNER’S MANUAL
TROUBLESHOOTING
Continued
WARNING: If you smell gas
Shut off gas supply.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbors phone. Follow the
gas suppliers instructions.
If you cannot reach your gas supplier, call the fire department.
IMPORTANT:
Operating heater where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.
POSSIBLE CAUSE
1. Metal expanding while heating or con-
tracting while cooling
1. Heater burning vapors from paint, hair
spray, glues, cleaners, chemicals, new
carpet, etc. (See
IMPORTANT
state-
ment above)
2. Low fuel supply
3. Gas leak. See Warning statement
at top of page
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Warning statement
at top of page
2. Control valve defective
1. Foreign matter between control valve
and burner
2. Gas leak. See Warning statement
at top of page
REMEDY
1. This is common with most heaters. If
noise is excessive, contact qualified ser-
vice person
1. Open window to ventilate room. Stop us-
ing odor causing products while heater
is running
2. Refill supply tank
3. Locate and correct all leaks (see Check-
ing Gas Connections, page 12)
1. Open window and/or door for ventilation
2. Contact local propane/LP gas company
3. Clean ODS/pilot (see Cleaning and
Maintenance, page 16)
1. Locate and correct all leaks (see Check-
ing Gas Connections, page 12)
2. Replace control valve
1. Take apart gas tubing and remove for-
eign matter
2. Locate and correct all leaks (see Check-
ing Gas Connections, page 12)
OBSERVED PROBLEM
Heater produces a clicking/ticking noise
just after burners are lit or shut off
Heater produces unwanted odors
Heater shuts off in use (ODS operates)
Gas odor even when control knob is in OFF
position
Gas odor during combustion
www.desatech.com