UNVENTED NATURAL GAS LOG HEATER
FIREPLACE MANUFACTURERS INC.
Thermocouple
Pilot Burner
Figure 25 - Correct Pilot Flame Pattern
Figure 26 - Incorrect Pilot Flame Pattern
INSPECTING
BURNERS
Check pilot flame pattern and burner flame
patterns often.
PILOT FLAME PATTERN
Figure 25 shows a correct pilot flame pat-
tern. Figure 26 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.
If pilot flame pattern is incorrect, as shown
in Figure 26
turn heater off (see To Turn Off Gas to
Appliance, page 15)
see Troubleshooting, pages 18 through 20
Thermocouple
Pilot Burner
OPERATING
HEATER
Continued
Figure 23 - Setting the Remote Selector Switch, Control Knob, and Flame Adjustment
Knob for Remote Operation
O
F
F
P
I
L
O
T
O
N
L
O
I
H
ON
OFF
REMOTE
Selector Switch in
Remote Position
Control Knob in
On Position
Flame Adjustment Knob
Figure 24 - Thermostat Hand-Held Remote Control Unit Selections
(GHRCTA Series Only)
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners
On or Off and
Allows You to
Choose the Auto
Setting
Shows
Temperature
Setting
The Log Heater
will Automatically
Cycle between
Pilot and the Heat
Setting that has
been Selected
IMPORTANT:
This remote control
has been specially engineered to take
an air temperature sample every 5.5
minutes in the auto mode. It will not
respond immediately to the tempera-
ture setting being turned up or down.
IMPORTANT:
The hand-held remote
control unit must be near the heater.
Do not keep the hand-held remote
control unit too close to the heater.
The thermostat on the hand-held re-
mote control unit will heat up too
quickly and turn the heater off.
3. To turn the burner off, press the
AUTO/ON/OFF button until OFF
lights. The pilot will remain lit.
IMPORTANT:
To turn the pilot off,
manually turn the control knob on
the heater to the OFF position.