www.fmiproducts.com
125078-01B24
INSPECTING BURNERS
Pilot
Burner
Ignitor/
Sensor
Figure 35 - Correct Pilot Flame Pattern
Sensing
Rod
Check pilot ame pattern and burner ame
patterns often.
pILOT ASSEMBLY
The pilot assembly is factory preset for the
proper ame. Alterations may have occurred
during shipping and handling. The pilot is
located on right hand side of burner.
The ame must envelope 1/4" of top of the
ignitor/sensor and grounding stem.
If your pilot assembly does not meet these
requirements:
• Turn the adjustment screw marked PILOT
clockwise to decrease or counterclockwise
to increase the ame to proper size (see
Figure 33, page 23). Do not remove the
adjustment screw.
• see Troubleshooting, page 26
BURNER FLAME pATTERN
Burner ames will be steady, not lifting or oat-
ing. Flame patterns will be different from unit
to unit and will vary depending on installation
type and weather conditions.
If the vent conguration is installed incorrectly,
ames will lift or "ghost". This can be danger-
ous. Inspect ames after installation to ensure
proper installation and performance.
Figure 36 shows a typical ame pattern.
If burner ame pattern differs from that de-
scribed:
• turn replace off (see To Turn Off Gas to
Appliance, page 23)
• see Troubleshooting, page 26
Figure 36 - Typical Flame Pattern
CLEANING AND MAINTENANCE
WARNING: Turn off replace
and let cool before cleaning.
CAUTION: You must keep
control areas, burners and
circulating air passageways of
replace clean. Inspect these
areas of replace before each
use. Have replace inspected
yearly by a qualied service
person. Fireplace may need
more frequent cleaning due to
excessive lint from carpeting,
bedding material, pet hair, etc.
GLASS DOORS
WARNING: Handle glass
door panels with care. Do not
strike, slam or otherwise abuse
glass. Do not operate replace
with the glass door unlatched,
removed, cracked or broken.
WARNING: Do not use
abrasive cleaners as this may
damage glass. Use a nonabra-
sive household glass cleaner to
clean glass. Do not clean glass