FMI GL36STE Gas Heater User Manual


 
www.fmiproducts.com
55173H 15
CLEANING AND
MAINTENANCE
WARNING: Installation and
repair should be done by a
qualied service person. The
applianceshouldbeinspected
before each use and at least
annuallybyaqualiedservice
person. More frequent clean-
ing may be required due to
excessivelintfromcarpeting,
beddingmaterial,pethair,etc.
Itisimperativethatthecontrol
compartments, burners and
circulatingairsystembekept
clean.
WARNING:Thelogscanbe
hot.Handleonlywhencool.
TO TURN OFF GAS
TO APPLIANCE
1. Turn off all electric power to the appliance
if service is to be performed.
2. Remove control access panel.
3. Close the gas valve.
OPERATING FIREPLACE
Continued
Figure 26 - Pilot
WARNING: Turn off gas and
electricalpowerbeforeservicing
appliance. Any safety screen
orguardremovedforservicing
mustbereplacedpriortooperat-
ing the appliance.
WARNING:Failuretokeep
the primary air opening(s) of
theburner(s)cleanmayresultin
sootingandpropertydamage.
Keep control compartment, logs, burner and area
surrounding logs clean by vacuuming or brushing
at least twice a year. Take care not to alter the set-
tings on the pilot assembly.
Do not use abrasive liquids or cleaners for cleaning
glass doors and trims. Any household glass cleaner
should sufce. Do not clean doors when hot. Allow
appliance to cool before cleaning.
TECHNICAL SERVICE
You may have further questions about installation,
operation or troubleshooting. If so, contact FMI
PRODUCTS, LLC’s Technical Service Depart-
ment at 1-866-328-4537. When calling please
have your model and serial numbers of your
heater ready.
You can also visit our web site at
www.fmiproducts.com.
SPECIFICATIONS
(V)GL36ST,(V)GL36STE
Maximum Input Rating at Altitudes: 2,000 ft.
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800
Btu/hr.
Manifold Pressure: 3.5 W.C. (.87 kPa)
Supply Pressure (in. of water): Minimum* - 4.5"
(1.12 kPa), Maximum - 11.0" (2.74 kPa)
Orice Size at Altitudes: 2,000 ft. - #30, 2,000 ft.
to 4,000 ft. - #31
(V)GL36STP,(V)GL36STEP
Maximum Input Rating at Altitudes: 2,000 ft.
- 42,000 Btu/hr., 2,000 ft. to 4,000 ft. - 37,800
Btu/hr.
Manifold Pressure: 11.0 W.C. (2.74 kPa)
Supply Pressure (in. of water): Minimum* -
12.0" (2.89 kPa), Maximum - 13.0" (3.23 kPa)
Orice Size at Altitudes: 2,000 ft. - #49, 2,000 ft.
to 4,000 ft. - #51
* For the purpose of input adjustment