FMI FVF30P Gas Heater User Manual


 
15
105192
OWNER’S MANUAL
1. STOP! Read the safety information,
column 1.
2. Make sure equipment shutoff valve
is fully open.
3. Press in and turn control knob clock-
wise
Clockwise
to the OFF position.
Figure 20 - Pilot
OPERATING
HEATER
FOR YOUR SAFETY
READ BEFORE
LIGHTING
WARNING: If you do not fol-
low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.
A.
This appliance has a pilot which must
be lighted by hand. When lighting the
pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all
around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.
WHAT TO DO IF YOU SMELL
GAS
Do not try to light any appliance.
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas sup-
plier, call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.
PILOT
OFF
LO
HI
Control Knob
Ignitor Button
Figure 19 - Control Knob and Ignitor Button Location
LIGHTING
INSTRUCTIONS
WARNING:
If fireplace has glass doors,
never operate this heater with
glass doors closed. If you oper-
ate heater with doors closed,
heat buildup inside fireplace will
cause glass to burst. Also if
fireplace opening has vents at
the bottom, you must open the
vents before operating heater.
You must operate this heater
with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Open damper or window to vent
smell. This will only last a few hours.
WARNING: Damper handle
will be hot if heater has been
running.
4. Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation in column 1. If you don’t
smell gas, go to the next step.
5. Slightly depress and turn control
knob counterclockwise
C-clockwise
to
the PILOT position. Keep control
knob pressed in for five (5) seconds
(see Figure 19).
Note:
You may be running this
heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.
If control knob does not pop out
when released, contact a qualified
service person or gas supplier for
repairs.
6. With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
burner. If needed, keep pressing ig-
nitor button until pilot lights.
Note:
If pilot does not light, contact
a qualified service person or gas sup-
plier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure on page 16.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note:
If pilot goes out, repeat steps
3 through 7.
8. Slightly depress and turn control
knob counterclockwise
C-clockwise
to
the HIGH position. The burner
should light. Set control knob to any
heat level between HIGH and LO.
(
Note:
Appearance of pilot assembly may
vary by model.)
Thermocouple
Ignitor
Electrode
Pilot Burner
Continued
Note:
Home owners generally prefer to
operate their heater with the chimney
damper closed. This will put all the heat
into the room. However, there may be
times you will desire the full flames of the
HI heat setting but will find the heat
output excessive. You can open the chim-
ney damper (if you have one) fully or
partially to release some of the heat.