FMI FMH26TP Indoor Fireplace User Manual


 
8
107106
PROPANE/LP VENT-FREE FIREPLACE SYSTEM
Note:
Your vent-free fireplace is designed to
be used in zero clearance installations. Wall or
framing material can be placed directly against
any exterior surface of your fireplace, except
where standoff spacers are integrally attached.
If standoff spacers are attached to your fire-
place, these spacers can be placed directly
against wall or framing materials.
Use the dimensions shown for rough open-
ings to create the easiest installation (see
Built-In Fireplace Installation, page 9).
CHECK GAS TYPE
Use only propane/LP gas. If your gas supply
is not propane/LP, do not install fireplace.
Call dealer where you bought fireplace for
proper type fireplace.
INSTALLATION ITEMS
Before installing fireplace, make sure you
have the items listed below.
external regulator (supplied by installer)
piping (check local codes)
sealant (resistant to propane/LP gas)
equipment shutoff valve *
test gauge connection*
ground joint union
sediment trap
tee joint
pipe wrench
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional CSA design-certified
equipment shutoff valve from your dealer.
See Accessories, page 26.
Note:
If desired, purchase a four-sided brass
trim kit for built-in installations. See Acces-
sories, page 26.
WARNING: A qualified ser-
vice person must install fireplace.
Follow all local codes.
You can recess firebox into the wall. You
can also position fireplace in the optional
cabinet or corner mantels.
IMPORTANT:
Only use optional cabinet or corner mantels
specified in this manual. Purchase the op-
tional mantel from your dealer (see Acces-
sories, page 26).
LOCATING FIREPLACE
WARNING: Never install the
fireplace
in a bedroom or a bathroom
in a recreational vehicle
where curtains, furniture,
clothing, or other flammable
objects are less than 36 inches
from the front, top, or sides of
the fireplace
as a fireplace insert
in high traffic areas
in windy or drafty areas
CAUTION: This fireplace cre-
ates warm air currents. These cur-
rents move heat to wall surfaces
next to fireplace. Installing fire-
place next to vinyl or cloth wall
coverings or operating fireplace
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT:
Vent-free fireplaces add mois-
ture to the air. Although this is beneficial,
installing fireplace in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Air for Combustion
and Ventilation, pages 5 through 7.
CAUTION: If you install the
fireplace in a home garage
fireplace pilot and burner must
be at least 18 inches above floor.
locate fireplace where moving
vehicle will not hit it.
Figure 7 - Mounting Clearances As Viewed
From Front of Fireplace Shown Built In
The Wall
Figure 8 - Mounting Clearances As Viewed
From Front of Fireplace Shown with
Optional Mantel
Top Of
Mantel Can
Be Flush
With Wall
Left
Side
CEILING
Right
Side
36"
Minimum
6"
Minimum
From
Sides Of
Fireplace
Left
Side
CEILING
36"
Minimum
FLOOR
Right
Side
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
systems circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: Maintain the mini-
mum clearances shown in Fig-
ures 7 and 8. If you can, provide
greater clearances from floor,
ceiling, and joining wall.
Note:
When installing fireplace directly on
carpeting, tile or other combustible material,
other than wood flooring, the fireplace shall
be installed on a metal or wood panel extend-
ing the full width and depth of the fireplace
0" Minimum To Top Surface Of Carpeting,
Tile Or Other Combustible Material
0" Minimum To Top Surface Of Carpeting,
Tile Or Other Combustible Material