www.fmiproducts.com
124979-01C18
WARNING: Burner will come
on automatically within one min-
ute when control valve is in the
1. STOP! Read the safety information.
2. Make sure equipment shutoff valve is fully
open.
3. Press in and turn control knob clockwise
to the OFF position (see Figure 36.
4. Wait ve (5) minutes to clear out any gas.
Then smell for gas, including near the
oor. If you smell gas, STOP! Follow “B”
in the safety information. If you don’t smell
gas, go to the next step.
5. Press in and turn control knob counter-
clockwise to the PILOT position.
Press in control knob for ve (5) seconds
(see Figure 26, page 19).
Note: You may be running this replace
for the rst time after hooking up to gas
supply. If so, the control knob may need
to be pressed in for 30 seconds or more.
This will allow air to bleed from the gas
system.
6. With control knob pressed in, press and
release ignitor button. This will light pilot.
The pilot is attached to the front burner. If
needed, keep pressing ignitor button until
pilot lights.
Note: If pilot does not stay lit, contact a
qualied service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
-
-
BEFORE LIGHTING smell all around the ap-
WHAT TO DO IF YOU SMELL GAS
Use only your hand to push in or turn the
-
the appliance and to replace any part of
LIGHTING
INSTRUCTIONS
WARNING: You must operate
screen is installed before run-
OPERATION