WARNING: Maintain the
minimum clearances shown

   

If your replace is to be used with an optional
mantel, the installation instructions included
with your mantel shows an approved method
of attaching the replace/mantel system to a
wall. IMPORTANT: Only use optional cabinet
or corner mantels specied in this manual.
Purchase the optional mantel from your dealer
(see Accessories, page 31).
If your replace is to be recessed into the wall,
see Built-In Fireplace Installation on page 10
to secure your replace into the wall.
CAUTION: If you install the

 

 

For convenience and efciency, install re-
place
where there is easy access for operation,
inspection and service
in coldest part of room
An optional blower kit is available from your
dealer. See Accessories, page 31. If planning
to use blower, follow instructions provided with
blower for power source.
Minimum Clearances For Side
Combustible Material, Side Wall and

A. Clearances from the side of the replace
cabinet to any combustible material and
wall should follow diagram in Figure 6.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
1
/2" from the wall. This com-
bustible material must be 4" from the side
of the replace opening (see Figure 7).
INSTALLATION
Continued
Figure 7 - Minimum Clearance for
Combustible to Wall
*Minimum 16" from Side Wall
*
Example
B. Clearances from the top of the replace
opening to the ceiling should not be less
than 36".
C. For mantel clearances, see Figure 11 on
page 12.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top 36", Left and Right Sides 6",
Bottom and Rear 0", Front 36"

Built-in installation of this replace involves
installing replace into a framed-in enclosure.
This makes the front of replace ush with
wall. Trim will extend past sides of replace
approximately 1/2". This will cover the rough
edges of the wall opening. If installing a built-
in mantel above the replace, you must follow
the clearances shown in Figure 11, page 12.
Follow the instructions below to install the
replace in this manner.
Actual Framing
Height 26" 26
7
/8"
Front Width 26
3
/4" 26
7
/8"
Depth 14
1
/4" 15
1
/4"
1. Frame in rough opening. Use dimensions
shown in Figure 8, page 11, for the rough
opening. If installing in a corner, use
dimensions shown in Figure 9, page 11,
for the rough opening. The height is 26
7
/
8
"
which is the same as the wall opening
above.