First Alert SA340 Smoke Alarm User Manual


 
USER’S MANUAL
Printed in Mexico
M08-0143-002 J1 05/07
INTRODUCTION
Thank you for choosing First Alert
®
for your Smoke Alarm needs. You
have pur
chased a state-of-the-art Smoke Alarm designed to provide
you with early war
ning of a fire. Please take the time to read this manual
and make the Smoke Alarm an integral part of your family’s safety plan.
Key Featur
es of the SA340 Smoke Alarm:
T
amper Resistant Lithium Powercell:
Pr
ovides continuous power for
up to 10 years. Power
cell cannot be removed.
Single T
est/Silence Button:
Allows you to test the Alarm or silence
nuisance alarms. Testing the Alarm assures you that the unit is function-
ing
correctly and ready to protect you and your family. The Alarm can
be silenced for up to 10 minutes in the event of a nuisance alarm.
Low power warning: The Alarm will sound a “chirp” once per minute
when the Alarm r
eaches the end of its service life and needs to be
r
eplaced.
Blinking Power Indicator: Confirms that the Smoke Alarm is r
eceiving
power.
© 2007 BRK Brands, Inc., a subsidiary of Jar
den Corporation.
3901 Liberty Str
eet Road, Aurora, IL 60504-8122
All rights reserved. Consumer Affairs: (800) 323-9005 • www.firstalert.com
FIRE SAFETY TIPS
Follow safety rules and pr
event hazardous situations: 1) Use smoking
materials properly. Never smoke in bed. 2) Keep matches or lighters
away fr
om childr
en; 3) Stor
e flammable materials in pr
oper containers;
4) Keep electrical appliances in good condition and don’
t overload elec-
trical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys
grease- and debris-free; 6) Never leave anything cooking on the stove
unattended; 7) Keep portable heaters and open flames, like candles,
away from flammable materials; 8) Don’t let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if
they are not working properly. Smoke Alarms that do not work cannot alert
you to a fir
e. Keep at least one working fire extinguisher on every floor, and
an additional one in the kitchen. Have fire escape ladders or other reliable
means of escape fr
om an upper floor in case stairs ar
e blocked.
BEFORE YOU INSTALL THIS SMOKE ALARM
IMPORTANT! Read “Recommended Locations for Smoke Alarms”
and “Locations to A
void for Smoke Alarms” befor
e beginning. This
unit monitors the air, and when smoke reaches its sensing chamber,
it alarms. It can give you more time to escape before fire spreads.
This unit can ONLY give an early warning of developing fires if it is
installed, maintained and located where smoke can reach it, and where
all r
esidents can hear it, as described in this manual. This unit will not
sense gas, heat, or flame. It cannot prevent or extinguish fires.
Understand The Dif
fer
ent T
ype of Smoke Alar
ms
Battery power
ed or electrical? Dif
ferent Smoke Alarms provide
different types of protection. See “About Smoke Alarms” for details.
Know Where To Install Your Smoke Alarms
Fire Safety Professionals recommend at least one Smoke Alarm on
every level of your home, in every bedroom, and in every bedroom
hallway or separate sleeping ar
ea. See “Recommended Locations
For Smoke Alarms” and “Locations To Avoid For Smoke Alarms” for
details.
Know What Smoke Alar
ms Can and Can’
t Do
A Smoke Alarm can help alert you to fir
e, giving you precious time
to escape. It can only sound an alarm once smoke reaches the
sensor. See “Limitations of Smoke Alarms” for details.
Check Your Local Building Codes
This Smoke Alarm is designed to be used in a typical single-family
home. It alone will not meet r
equir
ements for boarding houses,
apartment buildings, hotels or motels. See “Special Compliance
Considerations” for details.
WEEKLY TESTING
NEVER use an open flame of any kind to test this unit. You
might accidentally damage or set fir
e to the unit or to your
home. The built-in test switch accurately tests the unit’
s
operation as required by Underwriters Laboratories, Inc. (UL).
If the Alarm ever fails to test properly, replace it immediately.
Pr
oducts under warranty may be returned to the manufacturer
for
r
eplacement. See “Limited W
ar
ranty”.
DO NOT stand close to the Alar
m when the hor
n is sounding.
Exposur
e at close range may be har
mful to your hearing. When
testing, step away when hor
n starts sounding.
It is important to test this unit every week to make sure it is working
properly.
Using the test button is the recommended way to test this
Smoke Alarm. Pr
ess and hold the test button on the cover of the unit
until the alarm sounds (the unit may continue to alarm for a few seconds
after you release the button).
During testing you will hear a loud,
r
epeating hor
n patter
n: 3 beeps, pause, 3 beeps, pause.
Red LED
flashes.
HOW TO INSTALL THIS SMOKE ALARM
THE PARTS OF THIS SMOKE ALARM
FOLLOW THESE SIMPLE STEPS!
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
During an alarm, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause. Red LED flashes.
If the unit alarms get everyone out of the house immediately.
If the unit alarms and you are not testing the unit, it is warning
you of a potentially dangerous situation that requires your
immediate attention. NEVER ignore any alarm. Ignoring the
alar
m may r
esult in injur
y or death.
Use the Silence featur
e to stop an unwanted alar
m (caused by
cooking smoke, etc.), then open a window or fan the smoke
away fr
om the unit. The Smoke Alar
m will r
eset automatically.
WHA
T TO DO IN CASE OF FIRE
Don’
t panic; stay calm. Follow your family escape plan.
Get out of the house as quickly as possible. Don’
t stop to
get dr
essed or collect anything.
Feel doors with the back of your hand befor
e opening them.
If a door is cool, open it slowly. Don’t open a hot door. Keep doors
and windows closed, unless you must escape thr
ough them.
Cover your nose and mouth with a cloth (pr
eferably damp).
T
ake short, shallow breaths.
Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely.
Call the Fire Department as soon as possible from outside.
Give your address, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
Alarms have various limitations. See "Limitations of Smoke Alarms"
for details.
INSTALL THE MOUNTING BRACKET:
1.
To remove the mounting bracket from the
Smoke Alarm base, hold the Smoke Alarm
base firmly and twist the mounting bracket
counter
clockwise.
2.
Place the bracket on the wall or ceiling where
you want to mount the alarm.
3. Hold the mounting bracket against the ceiling
(or wall) and trace ar
ound the inside of the two
keyhole slots.
4.
Make a mark inside each outline for the drill holes.
5.
Put the unit wher
e it won’t get covered with dust when you drill
the mounting holes.
6.
Using a 3/16-inch (5 mm) drill bit, drill a hole through each
pencil mark.
7.
Insert the plastic screw anchors (in the plastic bag with screws)
into the holes. Tap the screw anchors gently with a hammer, if
necessary, until they are flush with the ceiling or wall.
8.
Line the mounting bracket up over the plastic screw anchors.
9. Screw the mounting bracket to the ceiling or wall through the
mounting slots using the two scr
ews provided.
10.
Tighten both screws all the way.
USING THE SILENCE FEA
TURE
The Silence Featur
e can temporarily quiet an unwanted alarm for up
to 10 minutes. T
o use this featur
e, pr
ess the “T
est/Silence” button. The
Alarm remains functional. The LED will flash every 10 seconds (for up
to 10 minutes) to r
emind you the alarm has been silenced. The flashing
LED will stop when the unit returns to normal operation.
The Silence Feature does not disable the unit—it makes it temporar-
ily less sensitive to smoke. For your safety, if smoke around the unit
is dense enough to suggest a potentially dangerous situation, it
will stay in alar
m, or may r
e-alar
m quickly
. If you do not know the
source of the smoke, do not assume it is an unwanted alarm. Not
responding to an alarm can result in property loss, injury or death.
All First Alert
®
Smoke Alarms conform to regulatory requirements,
including UL217 and ar
e designed to detect particles of combustion.
Smoke par
ticles of varying number and size are produced in all fires.
Ionization technology is generally mor
e sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in gr
eater amounts by flaming fires, which consume combustible
materials rapidly and spr
ead quickly. Sources of these fires may include
paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally mor
e sensitive than ionization
technology at detecting lar
ge particles, which tend to be pr
o-
duced in gr
eater amounts by smoldering fires, which may smolder
for hours before bursting into flame. Sources of these fires may include
cigar
ettes burning in couches or bedding.
For maximum pr
otection, use both types of Smoke Alar
ms on each
level and in ever
y bedroom of your home.
This unit will not aler
t hearing impaired residents. It is recom-
mended that you install special units which use devices like
flashing str
obe lights to alert the hearing impaired residents.
Do not connect this unit to any other alarm or auxiliary device.
It is a single-station unit that cannot be linked to other devices.
Connecting anything else to this unit may pr
event it fr
om working
properly.
This Smoke Alarm cannot detect smoke until you activate it.
Y
ou must activate the unit for it to r
eceive power fr
om the
powercell. Failure to activate the unit will prevent the alarm
from providing any warning of smoke or fire.
The powercell in this unit cannot be replaced—once it reaches
the end of its ser
vice life, you must install a new Smoke Alarm.
Y
ou must deactivate the unit before disposing of it.
Do not install this unit over an electrical junction box. Air currents
around junction boxes can prevent smoke from reaching the
sensing chamber and prevent the unit from alarming. Only AC
powered units are intended for installation over junction boxes.
Do not stand too close to the unit when the alarm is sounding.
It is loud to wake you in an emergency. Exposure to the horn at
close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to the
sensing chamber and prevent the unit from operating properly.
1
2 3
REGULAR MAINTENANCE
This unit has been designed to be as maintenance free as possible, but
ther
e ar
e a few simple things you must do to keep it working pr
operly
.
Test it at least once a week.
Clean the Smoke Alarm at least once a month; gently vacuum the
outside of the Smoke Alarm using your household vacuum’s soft
brush attachment. A can of clean compressed air (sold at computer
or of
fice supply stor
es) may also be used. Follow manufactur
er
instructions for use. Test the Smoke Alarm. Never use water,
cleaners or solvents since they may damage the unit.
If the Smoke Alarm becomes contaminated by excessive dirt, dust
and/or grime, and cannot be cleaned to avoid unwanted alarms,
replace the unit immediately.
Relocate the unit if it sounds frequent unwanted alarms. See
“Locations to A
void For Smoke Alarms” for details.
When the powercell becomes weak, the Smoke Alarm unit will “chirp”
about once a minute (the low power war
ning). This low power war
ning
should last for 30 days, but you should r
eplace the Smoke Alarm
immediately to continue your protection.
1
2
1. Test/Silence button
2. Power/alarm indicator LED
1. Mounting bracket
2. Mounting slots
3. Powercell
4. Deactivation Tab (located under label)
5. T
urn to attach to bracket
6. Turn this way to remove from bracket
INSERTING THE POWERCELL:
Y
ou must activate the powercell before attaching the Smoke
Alar
m to the bracket.
1. Turn Alarm upside down. Line up
the pins and snap the power
cell
into the Alarm.
2. The powercell cannot be removed
after it is locked into the Alarm.
If you have tr
ouble activating the
unit, call Consumer Affairs at:
1-800-323-9005 for assistance.
3.
Test the Smoke Alarm. Press and hold the test button on the
cover of the unit until the alarm sounds (the unit may continue
to alarm for a few seconds after you r
elease the button).
During testing, you will hear a loud, r
epeating horn pattern:
3 beeps, pause, 3 beeps, pause.
If the unit does not alarm
during testing, call Consumer Af
fairs for assistance.
ATTACH SMOKE ALARM TO MOUNTING BRACKET
1.
Line up the alignment tab on the unit with the alignment tab on
the mounting bracket. Push the unit toward the bracket, and
tur
n it clockwise until you feel it snap into place.
2.
Test the unit again. Press the test button until the horn begins
sounding.
During testing, you will hear a loud, r
epeating
horn pattern: 3 beeps, pause, 3 beeps, pause.
TO PERMANENTLY DEACTIVATE THE SMOKE ALARM
Alarm is sealed. The powercell is not replaceable. Once it reaches
the end of its service life, or after 10 years—whichever comes first—
you must install a new Smoke Alar
m.
After 10 years or after the “low power war
ning” sounds (whichever
comes first):
1.
Once you deactivate this unit, it will not detect smoke or alarm.
It cannot be r
eactivated. You must install a new unit to continue
your protection. Alarm will resist mounting to the bracket after
deactivation.
2. Use a flathead screwdriver to score
label along dotted line.
3. Use thumb to pull deactivation tab
outwar
d until tab snaps into place.
This will dischar
ge the powercell
and deactivate the unit.
4. Install a new Smoke Alarm
immediately!
TOOLS YOU WILL NEED:
This unit is designed to be mounted on the ceiling,
or on the wall if necessary.
• Pencil
Drill with 3/16” (5 mm)
drill bit
• Standard flathead
screwdriver
• Hammer
LIMITED W
ARRANTY
BRK Brands, Inc., ("BRK") the maker of First Alert
®
brand pr
oducts
warrants that for a period of ten years fr
om the date of purchase, this
pr
oduct will be free from defects in material and workmanship. BRK, at
its option, will repair or replace this product or any component of the
pr
oduct found to be defective during the warranty period. Replacement
will be made with a new or r
emanufactured product or component. If
the product is no longer available, replacement may be made with a
similar pr
oduct of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of
initial r
etail purchase and is not transferable. Keep the original sales
r
eceipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or retail stores selling BRK products do
not have the right to alter
, modify or any way change the terms and
conditions of this warranty
.
This warranty does not cover normal wear of parts or damage r
esulting
fr
om any of the following: negligent use or misuse of the product, use on
improper voltage or current, use contrary to the operating instructions,
disassembly
, repair or alteration by anyone other than BRK or an
authorized service center
. Further, the warranty does not cover Acts of
God, such as fire, flood, hurricanes and tornadoes or any batteries that
ar
e included with this unit.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except to
the extent pr
ohibited by applicable law, any implied warranty of
merchantability or fitness for a particular purpose is limited in duration
to the duration of the above warranty
. Some states, provinces or
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty
lasts, so the above limitations or exclusion may not apply to you. This
warranty gives you specific legal rights, and you may also have other
rights that vary from state to state or province to province.
How to Obtain W
arranty Service
Service:
If service is required, do not return the product to your retailer.
In or
der to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time,
Monday thr
ough Friday
. T
o assist us in serving you, please have the
model number and date of pur
chase available when calling.
For Warranty Service return to:
BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
This Smoke Alarm is designed to operate for 10 years, and is backed
by a 10-year limited warranty
. To date, the actual alarm, however, has
not been tested for 10 years. The power
cell in this Smoke Alarm is not
r
eplaceable. When it r
eaches the end of its service life, you must r
eplace
the entir
e Smoke Alarm to continue your protection.
IF YOU SUSPECT A PROBLEM
Smoke Alarms may not operate pr
operly because of a dead or weak
power
cell, a build-up of dirt, dust or grease on the Smoke Alarm cover,
or installation in an improper location. Clean the Smoke Alarm as
described in “Regular Maintenance,” and test the Smoke Alarm again.
If it fails to test pr
operly when you use the test button, or if the problem
persists, replace the Smoke Alarm immediately.
If you experience frequent non-emergency alarms (like those
caused by cooking smoke), tr
y relocating the Smoke Alarm.
If the alarm sounds when no smoke is visible, try cleaning or
relocating the Smoke Alarm. The cover may be dirty.
If the alarm no longer sounds during testing, replace the
Smoke Alarm! If the Smoke Alarm was properly activated, and
had previously alarmed during testing, the powercell is at the
end of its ser
vice life. (See “Regular Maintenance.”)
If the alarm will not silence when you use the Silence feature,
DO NOT IGNORE THE ALARM! This indicates a potentially
dangerous situation.
If the Smoke Alarm “chirps” about once a minute (for more
than 30 minutes), Replace the Smoke Alar
m! (See “Regular
Maintenance.”) This is the low power warning.
DO NOT TRY FIXING THE ALARM YOURSELF—THIS WILL VOID YOUR WARRANTY!
If the Smoke Alarm is still not operating pr
operly, and it is still under
warranty
, please see “How to Obtain Warranty Service” in the Limited
W
arranty below.
RECOMMENDED LOCATIONS FOR
SMOKE ALARMS
Installing Smoke Alar
ms in Single-Family Residences
The National Fir
e Pr
otection Association (NFP
A), r
ecommends one
Smoke Alarm on every floor, in every sleeping area, and in every bed-
room. In new construction, the Smoke Alarms must be AC powered
and interconnected. See “Agency Placement Recommendations” for
details. For additional coverage, it is r
ecommended that you install a
Smoke Alarm in all rooms, halls, storage areas, finished attics, and
basements, wher
e temperatur
es normally remain between 40˚ F (4˚ C)
and 100˚ F (38˚ C). Make sure no door or other obstruction could keep
smoke fr
om reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
On every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with the door partly
or completely closed.
In the hall near every sleeping ar
ea. If your home has multiple
sleeping areas, install a unit in each. If a hall is over 40 feet (12
meters) long, install an alarm at each end.
At the top of the first-to-second floor stairway, and at bottom of
basement stairway.
Specific requirements for Smoke Alarm installation vary from state to
state and fr
om region to region. Check with your local Fire Department
for current requirements in your area.
It is recommended AC or AC/DC
units be inter
connected for added protection.
INSTALLING SMOKE ALARMS IN MOBILE HOMES & RVS
For minimum security install one Smoke Alarm as close to each sleeping
area as possible. For more security, put one unit in each room. Many
older mobile homes (especially those built befor
e 1978) have little or no
insulation. If your mobile home is not well insulated, or if you ar
e unsure
of the amount of insulation, it is important to install units on inside walls
only
. Smoke Alarms should be installed where temperatures normally
r
emain between 40˚ F (4˚ C) and 100˚ F (38˚ C).
W
ARNING: Test units
used in RVs after the vehicle has been in storage, before every trip,
and once a week while in use. Failure to test units used in RVs as
described may r
emove your protection.
AGENCY PLACEMENT RECOMMENDATIONS
NFPA 72 (National Fire Code) Chapter 11
“For your information, the National Fir
e Protection Association's
Standard 72, reads as follows:”
“11.5.1 One- and T
wo-Family Dwelling Units.”
“11.5.1.1 Smoke Detection.
Where required by applicable laws, codes,
or standar
ds for the specified occupancy, approved single- and multiple
-station Smoke Alarms shall be installed as follows: (1) In all sleeping
r
ooms. Exception: Smoke Alarms shall not be required in sleeping
r
ooms in existing one- and two-family dwelling units. (2) Outside of
each separate sleeping area, in immediate vicinity of the sleeping
r
ooms. (3) On each level of the dwelling unit, including basements.
Exception: In existing one- and two family dwelling units, appr
oved
Smoke Alarms powered by batteries are permitted.”
“A.11.8.3 Are More Smoke Alarms Desirable? The required number
of Smoke Alarms might not pr
ovide r
eliable early warning protection
for those ar
eas separated by a door from the areas protected by the
required Smoke Alarms. For this reason, it is recommended that the
householder consider the use of additional Smoke Alarms for those
ar
eas for increased protection. The additional areas include the base-
ment, bedrooms, dining room, furnace room, utility room, and hallways
not pr
otected by the required Smoke Alarms. The installation of Smoke
Alarms in kitchens, attics (finished or unfinished), or garages is not
normally recommended, as these locations occasionally experience
conditions that can r
esult in improper operation.”
Califor
nia State Fire Marshal (CSFM)
Early war
ning detection is best achieved by the installation of fire detec-
tion equipment in all r
ooms and areas of the household as follows: A
Smoke Alarm installed in each separate sleeping area (in the vicinity, but
outside bedr
ooms), and Heat or Smoke Alarms in the living rooms, din-
ing r
ooms, bedrooms, kitchens, hallways, finished attics, furnace rooms,
closets, utility and storage rooms, basements, and attached garages.
LOCATIONS TO AVOID FOR SMOKE ALARMS
For best per
formance, AVOID installing Smoke Alarms in these areas:
Where combustion particles are produced. Combustion particles
form when something bur
ns. Ar
eas to avoid include poorly ventilated
kitchens, garages, and furnace rooms. Keep units at least 20 feet
(6 meters) from the sources of combustion particles (stove, furnace,
water heater
, space heater) if possible. In areas where a 20-foot
(6 m) distance is not possible – in modular, mobile, or smaller
homes, for example – it is recommended the Smoke Alarm be
placed as far fr
om these fuel-bur
ning sources as possible. The
placement recommendations are intended to keep these Alarms at
a reasonable distance from a fuel-burning source, and thus reduce
“unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm
is placed directly next to a fuel-burning source. Ventilate these
areas as much as possible.
In air streams near kitchens. Air currents can draw cooking smoke
into the sensing chamber of a Smoke Alarm near the kitchen.
In very damp, humid or steamy ar
eas, or dir
ectly near bathr
ooms
with showers. Keep units at least 10 feet (3 meters) away fr
om
showers, saunas, dishwashers, etc.
Where the temperatures are regularly below 40˚ F (4˚ C) or above
100˚ F (38˚ C), including unheated buildings, outdoor r
ooms, por
ches,
or unfinished attics or basements.
In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm
dir
ectly over the stove or range. Clean a laundry room unit frequently
to keep it free of dust or lint.
Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can
blow smoke away fr
om the unit, pr
eventing it fr
om reaching the
sensing chamber.
In insect infested areas. Insects can clog openings to the sensing
chamber and cause unwanted alarms.
Less than 12 inches (305mm) away from fluorescent lights.
Electrical “noise” can interfer
e with the sensor
.
In “dead air” spaces. “Dead air” spaces may prevent smoke from
reaching the Smoke Alarm.
A
voiding Dead Air Spaces
“Dead air” spaces may pr
event smoke fr
om r
eaching the Smoke Alarm.
To avoid dead air spaces, follow the installation recommendations below.
On ceilings, install Smoke Alarms as close to the center of the ceiling
as possible. If this is not possible, install the Smoke Alarm at least
4 inches (102 mm) fr
om the wall or cor
ner
.
For wall mounting (if allowed by building codes), the top edge of Smoke
Alarms should be placed between 4 inches (102 mm) and 12 inches (305
mm) from the wall/ceiling line, below typical “dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measured
horizontally
. Additional Smoke Alarms may be r
equir
ed depending on
the length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for
details on requirements for sloped or peaked ceilings.
SPECIAL COMPLIANCE CONSIDERA
TIONS
This Smoke Alarm alone is not a suitable substitute for complete fir
e
detection systems in places housing many people—like apartment
buildings, condominiums, hotels, motels, dormitories, hospitals, long-
term health car
e facilities, nursing homes, day care facilities, or group
homes of any kind—even if they were once single-family homes.
It is not a suitable substitute for complete fir
e detection systems in
war
ehouses, industrial facilities, commercial buildings, and special-
purpose non-residential buildings which require special fire detection
and alarm systems. Depending on the building codes in your ar
ea, this
Smoke Alarm may be used to pr
ovide additional protection in these
facilities.
The following information applies to all four building types below:
In new construction, most building codes require the use of AC or AC/DC
power
ed Smoke Alarms only. AC, AC/DC, or DC powered Smoke Alarms
can be used in existing construction as specified by local building codes.
Refer to NFPA 72 (National Fire Alarm Code) and NFPA 101 (Life Safety
Code), local building codes, or consult your Fir
e Department for detailed
fire protection requirements in buildings not defined as “households.”
1. Single-Family Residence:
Single family home, townhouse. It is r
ecommended Smoke Alarms be
installed on every level of the home, in every bedr
oom, and in each
bedr
oom hallway.
2. Multi-Family or Mixed Occupant Residence:
Apartment building, condominium. This Smoke Alarm is suitable for
use in individual apartments or condos, pr
ovided a primary fire detection
system alr
eady exists to meet fire detection requirements in common
areas like lobbies, hallways, or porches. Using this Smoke Alarm in
common ar
eas may not provide sufficient warning to all residents or
meet local fir
e protection ordinances/regulations.
3. Institutions:
Hospitals, day car
e facilities, long-term health care facilities. This Smoke
Alarm is suitable for use in individual patient sleeping/r
esident rooms,
pr
ovided a primary fire detection system already exists to meet fire
detection requirements in common areas like lobbies, hallways, or
por
ches. Using this Smoke Alarm in common areas may not provide
suf
ficient warning to all residents or meet local fire protection ordinances
/regulations.
4. Hotels and Motels:
Also boarding houses and dormitories. This Smoke Alarm is suitable
for use inside individual sleeping/r
esident rooms, provided a primary
fir
e detection system already exists to meet fire detection requirements
in common areas like lobbies, hallways, or porches. Using this Smoke
Alarm in common ar
eas may not provide sufficient warning to all
r
esidents or meet local fire protection ordinances/regulations.
LIMIT
ATIONS OF SMOKE ALARMS
Smoke Alarms have played a key r
ole in reducing deaths resulting from
home fir
es worldwide. However, like any warning device, Smoke Alarms
can only work if they are properly located, installed, and maintained, and
if smoke r
eaches them. They are not foolproof.
Smoke alar
ms may not waken all individuals.
Practice the escape
plan at least twice a year
, making sur
e that everyone is involved – from
kids to grandparents. Allow children to master fire escape planning and
practice befor
e holding a fire drill at night when they are sleeping.
If childr
en or others do not r
eadily waken to the sound of the smoke
alarm, or if there are infants or family members with mobility limitations,
make sur
e that someone is assigned to assist them in fir
e drill and in
the event of an emer
gency. It is recommended that you hold a fire drill
while family members are sleeping in order to determine their response
to the sound of the smoke alarm while sleeping and to determine
whether they may need assistance in the event of an emer
gency
.
Smoke Alar
ms cannot work without power.
DC operated units cannot
work if the power
cell is missing, deactivated, or dead, or if the power
cell
was not activated corr
ectly
. AC units cannot work if the AC power is cut
of
f for any reason (open fuse or circuit breaker, failure along a power line
or at a power station, electrical fire that burns the electrical wires, etc.).
If you are concerned about the limitations of DC or AC power, install
both types of units.
Smoke Alar
ms cannot detect fires if the smoke does not reach
the Alar
ms.
Smoke fr
om fires in chimneys or walls, on roofs, or on
the other side of closed doors may not r
each the sensing chamber and
set of
f the alarm. That is why one unit should be installed inside each
bedroom or sleeping area—especially if bedroom or sleeping area
doors ar
e closed at night—and in the hallway between them.
Smoke Alarms may not detect fire on another floor or area of the
dwelling. For example, a stand-alone unit on the second floor may not
detect smoke fr
om a basement fir
e until the fir
e spreads. This may not
give you enough time to escape safely. That is why recommended
minimum pr
otection is at least one unit in every sleeping area, and
every bedroom on every level of your dwelling. Even with a unit on
every floor, stand-alone units may not provide as much protection as
inter
connected units, especially if the fir
e starts in a r
emote ar
ea. Some
safety experts recommend installing interconnected AC powered units
with battery back-up (see “About Smoke Alarms”) or professional fire
detection systems, so if one unit senses smoke, all units alarm.
Inter
connected units may pr
ovide earlier warning than stand-alone
units since all units alarm when one detects smoke.
Smoke Alar
ms may not be hear
d.
Though the alarm hor
n in this unit
meets or exceeds current standards, it may not be heard if: 1) the unit
is located outside a closed or partially closed door, 2) residents recently
consumed alcohol or drugs, 3) the alarm is drowned out by noise from
stereo, TV, traffic, air conditioner or other appliances, 4) residents are
hearing impair
ed or sound sleepers. Special purpose units, like those
with visual and audible alarms, should be installed for hearing impaired
residents.
Smoke Alarms may not have time to alarm before the fire itself
causes damage, injury, or death, since smoke from some fires may
not r
each the unit immediately
. Examples of this include persons
smoking in bed, childr
en playing with matches, or fires caused by
violent explosions resulting from escaping gas.
Smoke Alar
ms are not foolproof.
Like any electr
onic device, Smoke
Alarms are made of components that can wear out or fail at any time.
You must test the unit weekly to ensure your continued protection.
Smoke Alarms cannot pr
event or extinguish fir
es. They ar
e not a
substitute for property or life insurance.
Smoke Alar
ms have a limited life.
The unit should be r
eplaced
immediately if it is not operating properly. You should always replace a
Smoke Alarm after 10 years fr
om date of pur
chase. W
rite the purchase
date on the space provided on back of unit.
First Alert
®
is a registered trademark of the First Alert Trust.
4 5
6
ABOUT
SMOKE
ALARMS
Batter
y or DC operated Smoke Alar
ms:
Pr
ovide pr
otection even
when electricity fails, provided the batteries or battery packs are fresh
and correctly installed or activated. Units are easy to install, and do not
r
equir
e pr
ofessional installation.
AC power
ed Smoke Alar
ms:
Can be inter
connected so if one unit
senses smoke, all units alarm. They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided
the batteries ar
e fr
esh and corr
ectly installed. AC and AC/DC units
must be installed by a qualified electrician.
Smoke Alarms for Solar or Wind Energy users and battery backup
power systems: AC power
ed Smoke Alarms should only be operated
with true or pur
e sine wave inverters. Operating this Smoke Alarm with
most battery-powered UPS (uninterruptible power supply) products or
squar
e wave or “quasi sine wave” inverters
will damage the Alar
m
.
If you are not sure about your inverter or UPS type, please consult with
the manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke
Alarms should be installed for the hearing impaired. They include a
visual alarm and an audible alarm hor
n, and meet the r
equir
ements of
the Americans With Disabilities Act. Can be inter
connected so if one
unit senses smoke, all units alarm.
Smoke alarms are not to be used with detector guards unless the
combination has been evaluated and found suitable for that purpose.
All these Smoke Alarms ar
e designed to pr
ovide early war
ning of fir
es if
located, installed and cared for as described in the user’s manual, and if
smoke r
eaches them. If you are unsure which type of unit to install, refer
to Chapter 2 of the National Fire Protection Association (NFPA) Standard
72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code).
National Fire Protection Association, One Batterymarch Park, Quincy,
MA 02269-9101. Local building codes may also require specific units in
new construction or in different areas of the home.
BEDROOM
BEDROOM
HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO MEET
NFPA RECOMMENDATIONS
RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM
KITCHEN
LIVING ROOM
DINING ROOM
MULTI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
KEY:
EXISTING HOMES
SMOKE ALARMS WITH SILENCE
FEATURES RECOMMENDED FOR
ADDITIONAL PROTECTION
BEDROOM
BEDROOM
HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
BEDROOM
BEDROOM
LIVING ROOM
DINING ROOM
MULTI-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
EXISTING HOMES
KITCHEN
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KEY:
SMOKE ALARMS WITH SILENCE
FEATURES RECOMMENDED FOR
ADDITIONAL PROTECTION
INTERCONNECTED
AC OR AC/DC
SMOKE ALARMS
BEDROOM
BEDROOM
HALL
LIVING ROOM KITCHEN
FINISHED BASEMENT
REQUIRED TO
MEET NFPA
RECOMMENDATIONS
RECOMMENDED
FOR ADDITIONAL
PROTECTION
BEDROOM
BEDROOM
LIVING ROOM
DINING ROOM
MULT I-STORY RESIDENCE
SINGLE-STORY RESIDENCE, APARTMENT,
MOBILE HOME
KEY:
NEW CONSTRUCTION
SMOKE ALARMS
WITH SILENCE
FEATURES
RECOMMENDED
FOR ADDITIONAL
PROTECTION
KITCHEN
Printed in Mexico M08-0143-002 J1 05/07
Replace Alarm 10 years after installation. Write the replacement
date in the space pr
ovided
on the Alar
m label.
For your r
ecor
ds, please r
ecor
d:
Date Purchased: _______________________________
Date Installed: ___________/____________Month/Y
ear
Replacement Date: ___________/____________Month/Y
ear
SMOKE ALARM WITH TEN-YEAR
NON-REPLACEABLE LITHIUM POWERCELL
Model SA340
IMPORTANT! PLEASE READ
CAREFULL
Y AND SAVE.
This user’
s manual contains
important information about
your Smoke Alarm’s operation.
If you ar
e installing this Smoke
Alarm for use by others, you
must leave this manual—or a
copy of it—with the end user
.
Model SA340