NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home. The
built-in test switch accurately tests the units operation as required
by Underwriters Laboratories, Inc. (UL). If you choose to use an
aerosol smoke product to test the Smoke Alarm, be certain to use
one that has been Listed to Underwriters Laboratories, Inc. Safety
Standards, and use it only as directed. Use of non-UL Listed prod-
ucts or improper use of UL Listed products may affect the Smoke
Alarms sensitivity.
If the Alarm ever fails to test properly, replace it immediately.
Products under warranty may be returned to the manufacturer for
replacement. See Limited Warranty at the end of this manual.
DO NOT stand close to the alarm when the horn is sounding.
Exposure at close range may be harmful to your hearing. When
testing, step away when horn starts sounding.
When your smoke alarm is in this mode…
This is what you should hear…
This is what you should see…
Normal Operating Condition
Test
Alarm
Nothing. Horn is silent.
Red Light flashes every minute.
Alarm Horn sounds loudly. Repeating horn
pattern: 3 beeps, pause, 3 beeps, pause.
Repeats for as long as unit is in alarm.
Horn sounds loudly. Horn pattern repeats twice:
3 beeps, pause, 3 beeps, pause.
Red Light flashes rapidly.
Red Light flashes rapidly.
Requires Service
A series of three rapid chirps, once every minute.
Red Light flashes every minute.
Low Battery Warning (Silenced)
Nothing. Horn is silent for up to eight hours.
A series of two rapid flashes, once a minute.
Low Battery Warning
Horn chirps once a minute.
Red Light flashes every minute.
Alarm (Silenced)
Nothing. Horn is silent for up to 15 minutes.
Red Light flashes rapidly.
UNDERSTANDING THE LIGHT AND HORN PATTERNS
WEEKLY TESTING
It is important to test this unit every week to make sure it is working
properly.
Using the test button is the recommended way to test this Smoke
Alarm. During testing, you will hear a loud, repeating horn pattern:
3 beeps, pause, 3 beeps, pause.
You can test this Smoke Alarm two ways:
Manually:
Press the Test/Silence button on the
alarm cover until alarm sounds for 3-5 seconds.
Using Your Remote Control: Standing no fur-
ther than 20 feet away from the Smoke Alarm,
aim your IR remote at the Smoke Alarm and
press the CHANNEL or VOLUME button for at
least 3-5 seconds.
If the alarm does not respond to your remote
control, there may be an obstruction between
you and the alarm, you may be standing too
far away, or your remote control may not be
compatible.
1
2
3
TO LOCK THE BATTERY COMPARTMENT
Do not lock the battery compartment until you activate the battery and
test the Smoke Alarm.
1. Install the battery so the termi-
nals on the battery match the
terminals on the Smoke Alarm.
Match + to + and - to -.
Push the battery in until it snaps
in securely and cannot be shak-
en loose. If the battery is not
snapped in completely, the unit
cannot receive battery power.
2. Push and hold test button until
the alarm sounds:
3 beeps, pause, 3 beeps, pause.
If the unit does not alarm during
testing, DO NOT lock the battery
compartment! Install a new battery
and test again. If the Smoke Alarm
still does not alarm, replace it
immediately.
3. Using needle-nose pliers or a
utility knife, detach one locking
pin from the mounting bracket.
4. Push the locking pin through the
hole near the battery door latch
on the back of the Smoke Alarm.
TO LOCK THE MOUNTING BRACKET:
1. Using needle-nose pliers,
detach one locking pin from
the mounting bracket.
2. Insert the locking pin through
the hole on the back of the
Smoke Alarm as shown in the
diagram.
3. When you attach the Smoke
Alarm to the mounting brack-
et, the locking pins head will
fit into a notch on the bracket.
TO UN-LOCK THE BATTERY COMPARTMENT
1. Remove the Smoke Alarm from
the mounting bracket.
If the unit is locked to the brack-
et, see the section
To Un-Lock the Mounting
Bracket.
2. Insert a flathead screwdriver
under the head of the locking
pin, and gently pry it out of the
battery compartment lock. (If you
plan to re-lock the battery com-
partment, save the locking pin.)
3. To re-lock the battery
compartment, close the
battery door and reinsert locking
pin in lock.
4. Reattach the Smoke Alarm
to the mounting bracket.
When replacing the battery, always
test the Smoke Alarm before re-
locking the battery compartment.
TO UN-LOCK THE MOUNTING BRACKET:
1. Insert a flathead screwdriver into
the rectangular cut-out on the
mounting bracket nearest to the
locking pin.
2. Pry the Smoke Alarm away from
the bracket by pushing up on
the screwdriver and turning the
Smoke Alarm counterclockwise
(left) at the same time.