First Alert C0400B Carbon Monoxide Alarm User Manual


 
brkelectronics.com
ARCHITECTURAL AND ENGINEERING SPEC
INSTALLATION OF ALARM
The carbon monoxide alarm shall be a First Alert Model CO400 (no display) or a CO410
(digital display) and shall provide at a minimum the following features and functions:
1. An electrochemical CO sensor.
2. The unit shall have a digital display with peak CO memory feature (CO410 only).
3. Powered by supervised 2 AA alkaline batteries and a solid state piezo horn rated at
85dB at 10 ft.
4. The CO sensor is adjusted not to detect CO levels below 30 PPM and will not
alarm when exposed to constant levels of 30 PPM for 30 days. It will alarm
at the following levels: 400 PPM CO between 4 and 15 minutes, 150 PPM CO
between 10 and 50 minutes and 70 PPM CO between 60 and 240 minutes.
5. A visual red LED power-on indicator to confirm unit is receiving power
or is in alarm.
6. A full function test button should check all alarm functions by simulating a CO
condition, causing the unit to alarm.
7. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8
hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
8. The unit shall be capable of operating between 40°F (4°C) and
100°F (38°C) and relative humidity between 10% and 95%.
9. The unit shall contain mounting hardware and shall be listed for wall mounting.
10. The unit shall at a minimum meet the requirements of UL2034, NFPA 720,
NFPA 101, ICC.
Installation of this alarm must conform to NFPA 720. Always check your local building
codes. Follow all instructions for placement as outlined in the user’s manual.
SHIPPING SPECS:
TECHNICAL SPECS
Individual Carton Dimensions 5.813 ”L x 2.938”W x 3.438”H
Weight 0.43 lbs. (CO400B)
0.48 lbs. (CO410B)
Cube 0.034 ft3
UPC 0 29054 00074 3 (CO400B)
0 29054 00097 2 (CO410B)
Master Carton Dimensions 7.4”L x 5.4”W x 6.1”H
Master Pack 6
Weight 2.92 lbs. (CO400B)
3.21 lbs. (CO410B)
Cube 0.14 ft3
I2 of 5 600 29054 00074 5 (CO400B)
600 29054 00097 4 (CO410B)
Pallet Information
Cases per Layer 45
Number of Layers 6
Cases per Pallet 270
Units per Pallet 1,620
Cube 49.6 ft3
Weight 788 lbs. (CO400B)
867 ibs. (CO410B)
©2009 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM2927
THE PARTS OF THESE CO ALARMS
1. Open door here 5. (Behind Cover) Alarm Horn
2. Test/Silence button 6. Peak Level Button (CO410B only)
3. POWER/ALARM Light 7. Digital Display (CO410B only)
4. AA Battery Compartment
Alarm Dimensions: 3.3”H x 4.8"L x 1.5"D
Weight: 5.5 oz. (CO400B)
6.2 oz. (CO410B)
Operating Voltage: Two 1.5V AA Alkaline Batteries
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates CO conditions, causing the unit to
alarm or temporarily silence the alarm
Alarm Reset: Automatic when explosive gas and/or CO clears
CO Sensor: Electrochemical
Indicator Lights/Sounds:
DC Power: Intermittent red Light
CO Alarm: Audio Alarm (4 beeps, pause, 4 beeps), rapidly
flashing red light
Digital Display: (CO410B only) Displays battery level, CO levels in parts per
million (PPM), Peak CO level
Listing: Listed to UL 2034 Standard
CAT.
CO400B/CO410B
CO
TOP VIEW SIDE VIEW BACK VIEW
4.8"
CO400B
3.3"
3.3"
1.5"
CO410B
4.8"
1.5"
2
3
4
1
5
6
3
4
2
1
5
7
CO400B CO410B