Firex SERIES 10000 Carbon Monoxide Alarm User Manual


 
1
110-1125C
SERIES 10000
MODEL COE: 120 V AC/DC CARBON MONOXIDE ALARM
WITH BATTERY BACKUP
SERIES 10200
MODEL COE-B: DC ONLY CARBON MONOXIDE ALARM
SERIES 10400
MODEL COEA: 120 V AC CARBON MONOXIDE ALARM
PLEASE READ AND SAVE THIS ENTIRE MANUAL
Installer: Please leave this manual with the product
Electrical rating:
120V AC, 60Hz, 0.05amp
Single or multiple station CO alarm
Model COE includes 9V battery back-up
TABLE OF CONTENTS
About This Carbon Monoxide Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Specifications and Important Product Information . . . . . . . . . . . . . . . . . . . . . . . .1
Where to Install This CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
How To Install This CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4
1. Installing an AC With Battery Back-Up Alarm . . . . . . . . . . . . . . . . . . . . . . . .3
2. Interconnecting AC Only and AC/DC Alarms . . . . . . . . . . . . . . . . . . . . . . . .3
If the Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Chart : Understanding the LED Lights and Horn Patterns . . . . . . . . . . . . . . .5 & 6
Troubleshooting the CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 & 6
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Symptoms of CO Poisoning and sources of CO in the home
Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Service and Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
About this Carbon Monoxide Alarm:
This CO alarm is designed to detect carbon monoxide gas. It is NOT designed to
detect smoke, fire, or any other type of gas. If this CO alarm sounds its alarm
horn, DO NOT assume that it is a false alarm. The alarm horn requires your
immediate action.
WARNING
Individuals with medical problems may consider using warning devices which provide
audible and visual signals for carbon monoxide concentrations under 30ppm.
SPECIFICATIONS AND IMPORTANT
PRODUCT INFORMATION
Product Features
Monthly Self-Test: Approximately every 30 days this alarm performs a silent
internal system test to verify sensor operation utilizing True Gas Testing. True
Gas Testing verifies that the CO sensor is nearing the end of its service life.
Traditional CO alarms test the sensor by simulating an alarm condition electrically.
This is the first CO sensor that runs a diagnostic test by generating a very small
and harmless amount of hydrogen gas. If the sensor is working properly, it WILL
NOT chirp. If the alarm chirps during the monthly self-testing, it is indicating a
problem with the unit. Refer to the charts on pages 5 and 6 for the appropriate
actions to take should this occur. You must still test the alarm weekly to verify
proper horn operation.
Trigger Alarm Locator™ (TAL™): Most interconnect tests trigger all alarm horns
simultaneously for the duration of the test. This unique system alternates between
a 10 second ALL ON cycle and a 50 second cycle where only the initiating alarm
is sounding.
Alarm Controlled Interconnect Test: In an interconnected system, this feature
will alarm the local unit first, then quiet the local unit while the remote units alarm.
Smart Quiet™ Low Battery 1: Allows the homeowners to silence the low battery
chirp for up to 10 hours, giving them time to go back to sleep and/or purchase a
fresh replacement battery.
Smart Quiet™ Low Battery 2: Indicates the battery no longer has enough
voltage to adequately protect in the event of a power outage or a battery-only
installation. The Smart Quiet™ feature will no longer silence the chirp.
THE BATTERY MUST BE REPLACED IMMEDIATELY.
Required Power Supply (Series 10000 and 10400 only)
This CO alarm requires constant 120-volt, AC power AND/OR a working 9-volt
battery to operate properly. This alarm WILL NOT work if AC power is not
connected or has failed or been interrupted for any reason AND the battery is
removed, drained or improperly connected. DO NOT use any other kind of battery
except as specified in this manual.
The following symbols identify the most important safety messages in
this manual.
DANGER
WARNING
CAUTION
When you see this symbol, be aware that if the
message is ignored, the hazard WILL result in
SEVERE bodily injury or death.
When you see this symbol, be aware that if the
message is ignored, the hazard CAN cause
SEVERE bodily injury or death.
When you see this symbol, be aware that if the
message is ignored, the hazard CAN or WILL
cause MINOR bodily injury.
Carbon Monoxide Alarm
©2006 INVENSYS CONTROLS AMERICAS
110-1125C Eng 2/22/06 11:32 AM Page 1