Firex PADC240 Smoke Alarm User Manual


 
SMOKE ALARM DESCRIPTION
Model GC240 Ionisation 230V AC smoke alarm with
False Alarm Control
Model I240C Ionisation 230V AC smoke alarm with 9V
battery back-up and False Alarm Control
Model IAR230C Ionisation 230V AC smoke alarm with recharge-
able battery backup and False Alarm Control
Model PG240 Optical 230V AC smoke alarm and False Alarm Control
Model PAD240 Optical 230V AC smoke alarm with 9V
&PADC240 battery back-up with False Alarm Control
Model PAR230 Optical 230V AC smoke alarm with rechargeable
battery back-up and False Alarm Control
SMOKE ALARM FEATURES
Interconnects with up to 36 Model GC240, I240C, PG240, PAD240, PADC240,
IAR230C, PAR230 smoke alarms. Unique power connector prevents
interconnection with incompatible smoke alarms or security systems.
Tamper-resist bracket quickly snaps into place and serves as a safeguard
against tampering.
Multi-purpose green and red LEDs indicate that the smoke alarm is receiving
AC power, working under normal operation, in alarm, or under False Alarm
Control.
Loud alarm horn—85 decibels at 3 metres (10 feet)—sounds to alert you of
an emergency.
•Test button checks smoke alarm operation.
Models GC240, I240C, PADC240 , PG240, PAR230 and IAR230C feature
False Alarm Control, which, when activated, quiets unwanted alarms for up to
15 minutes.
Models I240C, PAD240 and PADC240 will not attach to the mounting bracket
if a battery is not in the battery pocket. These models will also sound a short
beep about once a minute if the battery is weak or improperly connected.
Models IAR230C and PAR230 include permanent rechargeable
lithium batteries.
IMPORTANT SAFETY INFORMATION
PLEASE READ AND SAVE THESE
INSTRUCTIONS
W ARNING
AC smoke alarms require constant 230V AC, 50Hz power to operate
properly. Mains-powered smoke alarms WILL NOT work if AC power is not
connected or has failed or been interrupted for any reason. Models I240C,
PAD240 and PADC240 require a working 9-volt battery to operate properly in
the event of a power failure. Models IAR230C and PAR230 require a mini-
mum of 2 full days under mains power to reach full backup capacity. DO
NOT use any other kind of battery except as specified in this manual. DO
NOT connect this smoke alarm to any other type of smoke alarm or auxiliary
device, except those listed in this manual.
DO NOT remove or disconnect battery or turn off AC power to quiet
unwanted alarms. This will remove your protection. Open windows or fan the air
around smoke alarm to silence it. Models GC240, I240C, IAR230C, PG240,
PAR230 and PADC240 smoke alarms feature a False Alarm Control button which,
when activated, will quiet unwanted alarms for up to 15 minutes.
The Push-to-Test button accurately tests all smoke alarm functions.
DO NOT use any other test method. Test smoke alarm weekly to
ensure proper operation.
This smoke alarm should be installed only by a qualified
electrician.
This smoke alarm is designed to be used inside a single family
household only. In multi-family buildings, each individual living unit
should have its own smoke alarms. Do not install in non-residential build-
ings or places which house many people like hotels, motels, dormitories,
hospitals, nursing homes, or group homes of any kind. This smoke alarm
is not a substitute for a complete alarm system.
1
USER’S
MANUAL
PLEASE READ AND SAVE
INSTALLER: Please leave this manual with the product.
© 2002 Maple Chase 110-666C
BS5446 : Pt 1 : 2000
LICENSE NO. 7832
Model
I240C, GC240
IAR230C
Ionisation
Models
PG240, PAD240, PADC240,
PAR230
Optical
Printed
in
U.S.A.
!