Firex E and PB Smoke Alarm User Manual


 
IF YOUR HOUSEHOLD OR RESIDENCE HAS SEVERAL FLOORS, THERE
MUST BE AN ALARM ON EVERY FLOOR, INCLUDING IN THE BASEMENT.
See Figure 3.
Do install a smoke alarm in every
bedroom where a smoker sleeps.
Do install a smoke alarm in every
room and bedroom where electrical
appliances (such as portable heaters,
humidifiers or electric blankets) may
be operated while someone sleeps.
Do install a smoke alarm inside every
bedroom where someone sleeps with the
door closed. Smoke can be blocked by
the closed door, or the alarm may not
wake the sleeper if the door is closed.
Do install smoke alarms at both ends of a bedroom hallway if it is
more than 30 feet long.
Do install basement smoke alarms at the bottom of the basement
stairwell.
Do install second floor smoke alarms at the top of the first-to-second
floor stairwell, as long as no door or obstruction blocks the path of
the smoke to the alarm.
Do install a smoke alarm in a room where flammable household
chemicals or solvents are stored. For example, if you keep kerosene,
paint thinner or certain types of contact cements within your resi-
dence, install a smoke alarm in that room, unless not recommended
by a situation described in the section “WHERE YOU SHOULD NOT
INSTALL SMOKE ALARMS.”
Do install smoke alarms on the ceiling not closer than 4 inches to any
wall or corner, or on the wall at least 4 inches but no more than 12
inches from the ceiling. See Figure 4.
If your ceiling has radiant heat or has a lack of insulation to the out-
side, ceiling mounting of your smoke alarm is not advisable due to tem-
perature variations. You should follow the wall-mounting procedures.
If you have a peaked, sloped, gabled or cathedral-style ceiling, mount
your smoke alarm 4 to 36 inches (3 feet) MEASURED HORIZONTALLY
FROM THE HIGHEST POINT ON THE CEILING, as shown in Figure 4.
Do install smoke alarms in both rooms (areas) that are divided by a
partial wall extending 24 or more inches down from the ceiling. See
smoke alarms located in rooms B and C in Figure 4.
SPECIAL DIRECTIONS FOR INSTALLING
YOUR SMOKE ALARM IN MANUFACTURED
AND MOBILE HOMES
WARNING: SMOKE ALARMS MAY BE INSTALLED ON THE CEILINGS OF MANUFACTURED
AND MOBILE HOMES IF THERE IS ADEQUATE INSULATION IN THE CEILING
.
Install smoke alarms on walls only between 4 and 12 inches from the ceil-
ing. Install smoke alarms on inside walls in older homes or in homes where
you are not sure of the insulation level. In older homes (manufactured in
approximately 1976 or before) that have little or no insulation compared to
today’s standards, uninsulated metal outside walls and roofs can transfer
heat and cold from the outdoors, making the air right next to the wall or
roof hot or cold, compared to the rest of the air inside the room. These
layers of hot or cold air can prevent smoke from reaching a smoke alarm.
If your mobile home has this condition, put your smoke alarm on an inside
wall only, between 4 and 12 inches from the ceiling. If you are not sure
about the insulation in your mobile home or if you notice the outside walls
or ceiling are unusually hot or cold, put the smoke alarm on an inside wall.
FIGURE 1 FIGURE 2
FIGURE 3
FAMILY ROOM
DINING ROOM
KITCHEN
BEDROOM
BEDROOM
BEDROOM
LIVING ROOM
DENOTES SMOKE ALARM
WITH FALSE ALARM CONTROL
DENOTES SMOKE ALARM
KITCHEN
DINING
ROOM
BEDROOM
BEDROOM
BEDROOM
LIVING ROOM
FIGURE 4
3
110-631F English 12/12/06 3:37 PM Page 3