5. Test smoke alarm for proper operation (see WEEKLY TESTING OF
YOUR SMOKE ALARM section). The smoke alarm operates on a
9-volt battery. The normal battery operating life will be one (1) year.
The life of some batteries may be less.
6. Firex smoke alarms sold with Ultralife long-life lithium batteries
require replacement approximately every ten (10) years. Replace
the battery approximately every ten (10) years or when the low
battery signal sounds.
!CAUTION: YOU SHOULD ONLY USE THE BATTERIES SPECIFIED HERE OR ON THE LABEL OF
THE UNIT
.
For Models A, B, C, E and PB use: Eveready 216, 522 or 1222; Mallory
MN1604; Duracell MN1604; or Ultralife U9VL-J.
For Model E also use AA Heavy Duty for light power. The miniature lamp
operates on two (2) AA batteries. For replacement, use heavy-duty or
alkaline AA batteries: Eveready 1215, E91, or Duracell M15HD, MN1500.
!CAUTION: DO NOT USE ANY TYPE OF RECHARGEABLE BATTERIES
.
USING THE TAMPER RESIST LOCKING MECHANISM
To make the smoke alarm somewhat tamper resistant, a locking pin has
been provided in the base of the unit. It will help deter a child or other
individual from removing the smoke alarm from the bracket. See Figure 7.
This can be installed by the following directions.
1. Remove the break-away locking pin from the unit by rocking pin back
and forth.
2. Put the smoke alarm back on the mounting bracket. (See
sectionHOW TO INSTALL YOUR SMOKE ALARM.)
3. Using long-nose pliers, grab the head of the locking pin and insert
into hole located on the side of the smoke alarm. See Figure 8.
4. The Tamper Resist feature is now installed and complete.
To Remove:
5. Using long-nose pliers, grasp the head of the locking pin and pull the
pin completely out of the smoke alarm.
6. The smoke alarm can now be removed from the mounting bracket
with a counterclockwise twist.
8
FIGURE 7 FIGURE 8
LOCKING PIN
BASE OF
UNIT