591 Series Remote Accessory Controllers
591W Remote Indicator/Control Assembly w/White Single Gang Cover Plate
591R Remote Indicator/Control Assembly w/Red Single Gang Cover Plate
591S Remote Indicator/Control Assembly w/Stainless Steel Single Gang Cover Plate
592 Series Remote Accessory Controllers with Strobe
592WC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); White Double Gang Cover Plate
592WO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); White Double Gang Cover Plate
592RC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); Red Double Gang Cover Plate
592RO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); Red Double Gang Cover Plate
592SC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); Stainless Steel Double Gang Cover Plate
592SO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); Stainless Steel Double Gang Cover Plate
593 Series Remote Accessory Strobes (as an optional field upgrade kit for existing installed 591 Series Controllers)
593RC Strobe Assembly (Clear Lens); Red Double Gang Cover Plate
593RO Strobe Assembly (Opaque Lens); Red Double Gang Cover Plate
593SC Strobe Assembly (Clear Lens); Stainless Steel Double Gang Cover Plate
593SO Strobe Assembly (Opaque Lens); Stainless Steel Double Gang Cover Plate
593WC Strobe Assembly (Clear Lens); White Double Gang Cover Plate
593WO Strobe Assembly (Opaque Lens); White Double Gang Cover Plate
Products
Controls Americas
515 South Promenade Avenue
Corona California 92879-1736 USA
Cust. Svc. Telephone +1 800 951 5526
Cust. Svc. Facsimile +1 630 260 7299
iccacustomerservice@invensys.com
3505 Laird Road Unit #14
Mississauga Ontario L5L 5Y7 Canada
Cust. Svc. Telephone +1 800 387 7978
Cust. Svc. Facsimile +1 905 828 1265
iccacustomerservice@invensys.com
Technical Service
Telephone +1 800 445 8299
Facsimile +1 630 260 723
technicalservice@invensys.com
© 2006 Invensys Controls Americas 6/06 - #150-1991
Power Requirements: Standby 13mA
Alarm LED 22mA
Trouble with Buzzer 33mA
Trouble Silenced 33mA
Trouble without Buzzer 13mA
Alarm with Buzzer 37mA
Alarm Silenced with Buzzer 37mA
Alarm with Buzzer and Strobe 154mA
Alarm Silenced with Buzzer and Strobe 157mA
Lamp Test with Buzzer 62mA
Lamp Test with Buzzer Silenced 52mA
Sound Pressure: 60db @ 10 ft.
Dimensions: Single Gang Plate:
4-1/2” (114.3 mm) H x 2-3/4”
(69.85 mm) W
Double Gang Plate:
4-1/2” (114.3 mm) H x 4-1/2”
(114.33 mm) W
Wiring: 14-28 AWG. Solid or Stranded
Approvals: U.L. Listed for use with Firex duct
smoke detectors including all 2650
Series duct smoke detectors
UL URRQ, URRQ7.S7425 / CSFM / MEA
Silence and Ringback Functions
On the occasion where an audible alarm or trouble condition needs to be silenced while the detector
condition is inspected and remedied, the indicator/control module provides a silence function. The slide
switch located on the front of the module is pushed DOWN to activate the silence function.
Upon correction of the notified condition, the silenced buzzer will resume sounding. The ringback
feature serves as a reminder to reset the silence switch to the “normal”, UP position.
Note that the strobe module, when installed, will not stop operating when the silence function is engaged.
Wiring
For appropriate duct detector wiring terminals, please refer to detector and remote
accessory installation instructions.
Normal
“Standby”
Mode
Silenced
Mode
T
H
R
E
E
Y
E
A
R
W
A
R
R
A
N
T
Y
S
T
A
T
E
O
F
C
A
L
I
F
O
R
N
I
A
S
T
A
T
E
F
I
R
E
M
A
R
S
H
A
L
L
I
S
T
I
N
G
S
E
R
V
I
C
E
R
US
LISTED
268A Listed
MEA ACCEPTED