4
Testing Your Smoke Alarm cont.
The center test button accurately tests all functions. NEVER use an open flame from a match or lighter
to test this smoke alarm. You may ignite and set fire to the smoke alarm and your home.
Test all smoke alarms weekly as follows:
1. Look at the LED power indicator. A visual light flashing about once a minute indicates the smoke
alarm is receiving battery power. See “LED Power/Alarm Indicator” chart.
2. Firmly depress the test button for at least five (5) seconds [ten (10) seconds for Model CCPB]. The
smoke alarm will sound its alarm horn loudly. The alarm may sound for up to 10 seconds after
releasing the test button.
3. If smoke alarm does not sound, replace the smoke alarm immediately. If the smoke alarm is under
warranty, see warranty information at the end of this manual for more information.
REPLACE OR RETURN THE ALARM IF THE PUSH-TO-TEST FUNCTION DOES NOT OPERATE
PROPERLY AFTER FOLLOWING THE PROCEDURES OUTLINED ABOVE (see REPAIR on page 5).
LED Power/Alarm Indicator
The visual LED indicates the following:
Special Features of Model CC, CEC, CCPB and CPBC
Alarm Control (Quick-Quiet
™
) (Models CC, CEC CCPB, and CPBC only)
When activated, Alarm Control (Quick-Quiet
™
) quiets unwanted alarms for a maximum of 15 minutes.
Always check that the smoke alarm has activated in a false alarm situation. Be sure a real fire emergency
does not exist.
To use the Alarm Control
(Quick-Quiet
™
)
feature:
Press and release the test button during an unwanted alarm. The alarm should stop within ten seconds.
The LED will flash about once every 10 seconds. This means the smoke alarm is in Alarm Control
(Quick-Quiet
™
) mode.
If the smoke alarm does not go into Alarm Control
(Quick-Quiet
™
)
and continues to sound its loud alarm
horn, or if it initially goes into Alarm Control
(Quick-Quiet
™
) then resounds the alarm,
the smoke is very
heavy. This is possibly a dangerous situation—-take emergency action immediately.
Safety Light (Model CEC only)
Model CEC features a Safety Light. This light turns on when the smoke alarm sounds. The Safety Light
is a miniature lamp which will last up to 15 hours of continuous operation. Its purpose is to assist in pro-
viding light in the escape route during a fire.
If the Safety Light does not turn on when the smoke alarm is tested, check the batteries. Replace the
batteries if necessary.
IMPORTANT: Smoke alarms with the Safety Light require two (2) AA batteries to operate the Safety
Light. These batteries are in addition to the 9-volt battery used to operate the smoke alarm.
Chamber Test Feature (Models CCPB and CPBC only)
Once a minute Models CCPB and CPBC perform a chamber test. If at any time the unit chirps and the
LED does not flash–see MAINTENANCE AND CLEANING section of this manual.
Battery Replacement
Replace battery at least once a year or immediately when the low battery signal (a chirp) sounds once a
minute. Use only the following batteries as replacements in this smoke alarm: Eveready 522 and 1222
(except Model CCPB), or Duracell MN 1604. Long Life Lithium replacement battery is Ultralife U9VL-J.
NOTE: For Model CEC, replace Safety Light batteries with two AA size batteries. Replace all batteries
at the same time.
WARNING
DO NOT USE ANY OTHER TYPE OF BATTERY, EXCEPT AS SPECIFIED IN THIS
MANUAL. DO NOT USE RECHARGEABLE BATTERIES.
1. Turn smoke alarm counter-clockwise to detach from mounting plate.
2.
From back of smoke alarm, lift tab to open battery pocket door (Models CB, CC and CPBC only).
Remove battery from pocket. Disconnect and discard drained battery from battery connector.
3. Connect a fresh, 9-volt battery to connector. The battery will fit only one way. Be sure battery con-
nector is securely attached to battery terminals.
NOTE: For Model CEC, replace Safety Light batteries with two AA size batteries. Replace all batteries at the
same time.
4. Push test button for at least five (5) seconds [ten (10) seconds for Model CCPB]. The alarm horn
should sound. This means the battery is connected properly.
5. Place battery into battery pocket. Close battery pocket door. Push down until it snaps into place.
6. Reattach smoke alarm to mounting plate. To do so, turn smoke alarm clockwise until it snaps into
mounting plate.
7. Test smoke alarm using test button as described on page 3, TESTING YOUR SMOKE ALARM.
Maintenance and Cleaning
In addition to weekly testing, this smoke alarm requires yearly battery replacement, and periodic cleaning
to remove dust, dirt, and debris. Long Life Lithium battery can be expected to last as long as five (5)
years, but is warrantied for one (1).
Cleaning
Clean the smoke alarm at least once a month to remove dust, dirt, or debris as follows:
• Using the wand attachment of a vacuum cleaner, vacuum all sides and cover of smoke alarm. Be sure
all the vents are free of debris.
• If necessary, remove battery and use a damp cloth to clean smoke alarm cover.
IMPORTANT: Do not attempt to remove the cover or clean inside the smoke alarm. THIS WILL VOID
YOUR WARRANTY.
!
Blinks once a minute
Normal operation–smoke alarm is receiving battery power
Blinks once a second
Smoke is detected; audible alarm will simultaneously sound
Models CC, CEC, CPBC and CCPB only:
Blinks once every 10 seconds
Alarm Control (Quick-Quiet
™
) is actively quieting an unwant-
ed alarm
110-1011E English 12/12/06 10:10 AM Page 4