Field Controls UV-18X Air Cleaner User Manual


 
Page 5
Figure 20
8. Insert lamp through hole until lamp cannot be inserted any further. (See Figure 16)
9. Swing swivel bracket over end of lamp. Hand-tighten the wing nut on stud. (See Figure
17) Be careful not to over tighten the wing nut. The porcelain at the lamp base may
crack when over tightened.
10. Plug ballast plug into end of lamp. (See Figure 18)
11. Replace cover on unit. Tighten side screws. (See Figure 19 & 20)
12. Plug the power cord into a standard electrical outlet.
NOTE: Seal the joints and seams of the plenum near the mounting
location to reduce any direct viewing of light. (See Figure 1)
13. Flip switch on box to the ‘ON’ position. (Light on switch should be on indicating power.)
14. Look through view port in the box cover to be sure lamp is working. You should see a blue glow. (The view port
is covered with a plastic lens that blocks the UVC rays.)
15. If the lamp is not glowing, follow steps 8-14 again. If lamp still does not glow, contact technical support at 1-252-
522-3031 for further assistance.
Fi
g
ure 16
Figure 18
Figure 19
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause permanent eye damage o
r
blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum. Avoid touching the glass portion of the lamp with you
r
hands.
Figure 17