Field Controls UV-12HPC Air Cleaner User Manual


 
Page 11
IX. TROUBLESHOOTING GUIDE
1. If the LED is illuminating a “YELLOW” color and the circuit board alarm beeps every 15 minutes, the lamp should
be replaced soon.
2. If the LED is illuminating a “RED” color and the circuit board alarm beeps every 5 minutes, the lamp should be
replaced immediately.
3. If the lamp does not light up, replace lamp.
4. If the lamp still does not light up after replacing the lamp, replace ballast.
X. REPLACEMENT PARTS LIST
MODEL
LAMP
(Field Controls Part Number)
CIRCUIT BOARD
(Field Controls Part Number)
BALLAST
(Field Controls Part Number)
UV-12C 46365401 46436300 46365511
UV-18C 46365402 46436300 46365512
UV-28C 46365403 46436300 46365510
UV-28 46365403 N/A 46365503
UV-12HP 46365401 N/A 46365511
UV-18HP 46365402 N/A 46365512
UV-28HP 46365403 N/A 46365510
UV-12HPC 46365401 46436300 46365511
UV-18HPC 46365402 46436300 46365512
UV-28HPC 46365403 46436300 46365510
For replacement parts, contact your local heating service company. Any questions, please contact Field Controls at:
Phone: 252-522-3031 Fax: 252-522-0214 Email: sales@fieldcontrols.com
XI. FLEX DUCT INSTALLATION
For installations on duct systems with a metallic main duct and flex duct branches, follow the instructions in figure 26
below.
Figure 26