Figure 1
INSTALLATION
WHERE TO INSTALL THE CLEARWAVE
1. For water supply applications, locate where the main water supply pipe enters the home or
building. Point of use applications such as dishwashers, ice makers, boilers, water heaters
etc., attach the ClearWave™ unit to the water supply line to that particular appliance. For
long system piping lengths or high level calcium water, mount a CW-HD-1 to point of use
appliances.
2. Find a suitable location to install the ClearWave™ on the water supply pipe before the
piping branches off to supply water throughout the building.
H
OW TO INSTALL THE CLEARWAVE
1. One set of mounting brackets are provided, for mounting the ClearWave™ onto 1-1/2 inch
to 4 inch water pipes or wall mounted near the selected pipe area. Mount the mounting
brackets to the base of the ClearWave™ by using the screws provided. Mount the
ClearWave™ onto the pipe with wire ties or to the wall with appropriate fasteners. (see
Figure 1) For pipe mounting, the wall mount tabs should be removed from the mounting
brackets. (see Figure 2)
2. Plug the antennas into each end of the housing, to the appropriate wire wrap connections
(e.g. “CW” for clockwise wrapping and “CCW” for counter clockwise wrapping). If longer
wires are needed, up to 50 feet of 12Ga stranded wire can be added to the antenna wires
with an insulated butt end wire connector or they can be replaced with 60 feet of 12Ga
stranded wire.