Festool CT MINI Vacuum Cleaner User Manual


 
3
Before turning the switch to the
Auto position, make sure that the tool
connected to the tool plug socket is switched off.
When you turn the switch to Auto the dust
extractor will not come on until you turn on the
tool connected to the tool plug socket. When you
turn off the tool, the dust extractor will
automatically switch off. When you turn the tool
back on, the dust extractor will automatically
start.
Suction force regulator (1.2)
The suction force regulator lets you set the
suction force that works best for the material to
be vacuumed up.
Connecting an electric tool
Observe the maximum connected load on the
tool plug socket (see Technical Data). The tools
rated power consumption must not exceed this!
Plug the tool power cord to the tool plug socket
(1.3).
Make sure the tool is switched off
when you plug or unplug it!
Intended use
This dust extractor is designed for the aspiration
and evacuation of non-toxic, non-hazardous
dusts, dirt, sand, shavings etc., and for
vacuuming water.
This dust extractor is designed in accordance with
IEC 60 335-1 and IEC 60 335-2-69 for a higher
loading in industrial use.
The user is solely responsible for
any damage or accident caused by using this
machine for other than its intended purpose.
Getting started
Electrical connection
The operating voltage shown on the specification
plate must be the same as the mains power
voltage (wall socket).
Make sure that the dust extractor
is switched off when you plug in the power cord.
On/off switch (1.1)
In position O the dust extractor is switched off
and the tool plug socket (1.3) is dead.
Two modes of operation are possible:
a) Switch at MAN (manual control):
The tool plug socket is live.
Before turning the switch to the
MAN position, make sure that the tool
connected to the tool plug socket is switched off.
When you turn the switch to MAN the extractor
motor will start immediately and will stay on as
long as the switch is at this position.
You can also use this mode of operation without
a tool connected to the tool plug socket.
b) Switch at Auto (automatic tool-
triggered operation):
The tool plug socket is live.
No adapter should be used with this appliance.
If the appliance must be reconnected for use on
a different type of electric circuit, the
Technical data CT MINI
Power consumption 400 - 1,200 W
Max. connected load to tool plug socket 1,200 W
Total connected load max. (vacuum cleaner and
plug socket) 2,400 W
Max. airflow volume, turbine 168 m
3
/h (6,04 cu.ft./h)
Max. vacuum, turbine 20,000 Pa
Filter surface 5,000 cm
2
(775 sq. in.)
Suction hose, diameter x length 22 mm x 3,5 m (0.87 in. x 11.48 ft.)
Tank capacity 10 l (2.6 gal.)
Dimensions L x W x H 440 x 340 x 420 mm (17.3 x 13.4 x 16.5 in.)
Weight 9.5 kg (21 lbs)
Power cord length 7.5 m (24.6 ft.)
Protection type IP X4
reconnection must be made by qualified service
personnel.
SAVE THESE INSTRUCTIONS