Fedders CH42ACD1VF Heat Pump User Manual


 
Product Specifications
3
Specifications subject to change without notice.
SEER
Seasonal Energy Efficiency Ratio
COP Coefficient of Performance
TDR Time – Delay Relay
HSPF Heating Seasonal Performance Factor
EER Energy Efficiency Ratio
NOTES:
1. Tested combination per ARI 210/240 standard. Fedders air handlers contain the TDR as standard equipment.
2. Supplemental electric heat is not included.
3. Ratings are based on:
Cooling Standard: 80ºF db 67ºF wb indoor entering air temperature and 95ºF db air entering outdoor unit.
High – Temp Heating Standard: 70ºF db indoor entering air temperature and 47ºF db 43ºF wb air entering outdoor unit.
Low – Temp Heating Standard: 70ºF db indoor entering air temperature and 17ºF db 15ºF wb air entering outdoor unit.
ARI CERTIFIED COMBINATION RATINGS
UNIT
SIZE
OUTDOOR
MODEL
INDOOR
MODEL
FACTORY
SUPPLIED
ENHANCEMENT
COOLING HEATING
TOTAL
CAPACITY
SEER EER
HIGH TEMP LOW TEMP
HSPF
CAPACITY COP CAPACITY COP
18
CH18ABD1VF AFPB24A1 TXV, TDR 18,000 13.0 11.0 17,300 3.42 11,100 2.36 8.2
CH18ABD1VF AFPB24B1 TXV, TDR 18,000 13.0 11.0 17,300 3.42 11,100 2.36 8.2
24 CH24ACD1VF AFPB24B1 TXV, TDR 24,000 13.0 11.4 24,000 3.42 15,000 2.20 8.2
30 CH30ACD1VF AFPB36A1 TXV, TDR 28,000 13.0 11.5 28,000 3.50 18,200 2.30 8.2
36 CH36ACD1VF AFPB36A1 TXV, TDR 34,000 13.0 11.5 34,000 3.50 22,000 2.50 8.2
42
CH42ACD1VF AFPC48A1 TXV, TDR 40,000 13.0 11.5 40,000 3.42 23,000 2.30 8.2
CH42ACD1VF AFPC48B1 TXV, TDR 40,000 13.0 11.5 40,000 3.42 23,000 2.30 8.2
48 CH48ACD1VF AFPC48B1 TXV, TDR 46,000 13.0 11.5 44,000 3.42 28,400 2.50 7.8
60 CH60ACZ1VF AZFPC60B1 TXV, TDR 56,000 13.0 11.2 56,000 3.42 38,000 2.30 8.2