Fedders C12 Heat Pump User Manual


 
C12 High Efficiency Series
OUTDOOR
UNIT
MODEL*
EVAPORATOR
COIL
RATINGS AT STANDARD CONDITIONS
COOLING DATA AT EXTENDED OUTDOOR AMBIENTS °F.M.B.T.U.H.
BTUH
SEER
CFM
80 85 90 95 100 105 110 115
COOLING PERFORMANCE DATA MATCHING EVAPORATOR COIL
C1218BBD
E3009A 19000 12 600
TOTAL 20 500 20 200 19 600 19 000 18 500 18 000 17 400 16 900
SENSIBLE 15 750 15 550 15 100 14 650 14 200 13 800 13 450 13 150
C1224BBD
E3618A 23000 12 800
TOTAL 25 400 24 600 23 800 23 000 22 000 20 900 19 900 18 800
SENSIBLE 19 500 18 900 18 200 17 500 16 850 16 000 15 250 14 500
C1230BBD
E3618A 30000 12 1000
TOTAL 32 200 31 300 30 500 30 000 28 500 27 500 26 400 25 300
SENSIBLE 24 800 24 100 23 400 23 250 22 150 21 350 20 250 19 450
C1236BBD
E4824A 35400 12 1150
TOTAL 36 700 36 300 35 900 35 400 34 100 32 600 31 200 29 700
SENSIBLE 28 200 27 950 27 650 26 900 26 000 24 800 24 000 22 750
C1242CBD
E6026A 42000 12 1350
TOTAL 43 300 42 900 42 400 42 000 41 000 40 000 39 000 38 000
SENSIBLE 33 700 33 400 33 000 31 700 31 400 30 800 29 950 29 200
C1248CBD
E6026A 47500 12 1550
TOTAL 49 700 48 500 47 300 46 000 44 400 43 000 41 500 39 800
SENSIBLE 38 200 37 350 36 650 35 800 34 400 33 450 32 400 31 050
C1260CBD
E6037A 54000 12 1850
TOTAL 57 700 56 300 55 200 54 000 52 850 51 700 50 500 49 400
SENSIBLE 44 100 43 600 42 500 41 850 41 200 40 050 39 100 38 600
*Basic model number only. See unit nomenclature on the last page for exact model number.
FOOTNOTES:
Amps at 104˚F OD temp. 80˚F DB / 67˚F WB indoor temp. Time delay type fuse for HACR Circuit Breaker. Requires time delay relay to obtain
SEER rating. For indoor coils nomenclature see indoor coil specification sheet. Air handler includes Evaporator Coil.
MODEL NUMBER C1218BBD1VF C1224BBD1VF C1230BBD1VF C1236BBD1VF C1236BBD3VF C1236BBD4VF
PERFORMANCE DATA
NOMINAL COOLING BTU/H 19 000 23 000 30 000 35 400
SEER BTU/H-W 12.0 12.0 12.0 12.0
CFM 600 800 1000 1150
VOLTS/HZ/PHASE 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/1 208-230/60/3 460/60/3
VOLTAGE RANGE 197-253 197-253 197-253 197-253 187-253 415-508
OPERATING CURRENT AMPS 8.8 10.6 12.5 17.9 12.2 6.4
MIN. WIRE AMPACITY 10.5 15.2 19.7 23.3 15.2 8.0
MAX. HACR BREAKER 15 20 25 35 20 15
COMPRESSOR DATA
RLA 7.8 9.6 11.5 16.1 10.4 5.2
LRA 47 56 73 88 77 39
FAN DATA
DIAMETER 18 INCH / 3 BLADE 18 INCH / 3 BLADE 18 INCH / 3 BLADE 18 INCH / 4 BLADE
MOTOR TYPE PSC PSC PSC PSC
HP (W) / FLA 1/6 / 1.0 1/6 / 1.0 1/6 / 1.0 1/5 / 1.8 1/4 / 1.2
RPM 1075 1075 1075 1075
CFM 1800 1800 1800 2400
OUTDOOR COIL
TYPE ENHANCED ALUMINUM PLATE FIN / RIFLED COPPER TUBE
FACE AREA 8.1 9.8 12.0 12.0
O.D. / F.P.I.-ROWS 5/16 / 18-1 5/16 / 18-1 3/8 / 18-1 3/8 / 20-1
REFRIGERANT LINE CONNECTIONS (SERVICE VALVE PORT I.D.)
LIQUID 3/8 ID 3/8 ID 3/8 ID 3/8 ID
VAPOR 3/4 ID 3/4 ID 3/4 ID 3/4 ID
WEIGHTS
NET WEIGHT — lbs. 117 139 146 148
SHIPPING WEIGHT — lbs. 123 146 155 156
MODEL SPECIFICATIONS