Fantom Vacuum FS801 Vacuum Cleaner User Manual


 
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS cont.
WARNING: Always remove the power
plug from the wall outlet before
assembling or removing accessories.
INSERTING THE TELESCOPIC
TUBE INTO THE MAIN UNIT
Insert the telescopic tube into the hole
next to the dust cup handle. Make
sure that the slot in the handle fits
correctly into the opening. (See
illustration.)
To remove the telescopic tube, press
the telescopic tube release button and
pull the tube up.
EXTENDING THE TELESCOPIC
TUBE
Push the plastic button and pull out the
smaller tube. See illustration below
.
ATTACHING THE FLOOR BRUSH
TO THE MAIN UNIT
Insert the floor brush into its location,
in the direction of the arrow.
To remove the floor brush from the
main unit, press on the floor brush
release button and pull the floor brush
out.
ATTACHING THE HOSE TO THE
MAIN UNIT
Hold the end of the hose (see
illustration below).
Insert the hose into the hose
connector (see arrow in illustration).
Warning: After each Use -
Always remove the Filter
Assembly and the Dust Cup
Cover with the Debris Screen,
then vigorously “TapClean” HEPA
Filter and clean Debris Screen
until no more dust can be
removed.
4.Hold the HEPA filter
by the edges and
vigorously “TapClean”
the HEPA Filter dirty
side down on a hard,
flat surface until no
more dust is observed
falling out from
between the pleats of
the filter.
5. Rinse the non-woven pre-filter and
let d\air dry completely for 24 hours.
6. Insert the non-woven pre-filter.
7. Reinstall the HEPA filter in the
vacuum.
8. To Separate the Debris Screen from
the dust cup, hold the dust cup in one
hand and turn the dust cup cover
counter clockwise and pull apart. To
clean the Debris Screen, we
recommend that
you rinse it under
lukewarm running
water to remove
the dirt that
accumulates on it, but
always allow 24 hours to air dry
before inserting back into the vacuum.
Warning: Always unplug the
unit from electrical outlet before
opening the Dust Cup (container).
2. To empty the dust
cup container,
press on the trap
door release button
that is on the back
side of the dust cup
container.
Dust
Cup
Release
Button 2
Dust
Cup
Release
Button 1
HEPA
Filter
Non-Woven
Pre-Filter
3. The HEPA filter is located underneath
the dust cup container. (See
illustration.) Remove the non-woven
pre-filter. Remove the HEPA filter,
hold the edges and pull it out slowly.
Emptying the Dust Cup Container
and Cleaning / Changing the Non-
Woven Pre-Filter, HEPA Filter &
Debris Screen
Important: Do NOT use the vacuum
without the HEPA filter in place.
1. To remove the dust cup container,
first press on the dust cup release
button (1) that is located on the dust
cup handle and at the same time
press on the dust cup release button
(2) that is on the side of the upper
housing. See illustration below. Then
pull the dust cup container out.
IMPORTANT
, Please Note : The
“TapClean” HEPA Filter will stop most of
the tiniest dust particles from re-entering
the air you breathe. In fact it stops 99.97%
of all particles as small as 0.3 microns -
many times smaller than a human hair!!!
Because of this incredible filtration
performance, the HEPA Filter will quickly
accumulate, inside the white filter folds,
many fine dust particles that are difficult to
see but which will eventually block or
reduce your suction power - if not cleaned
properly.
7 4