Faber WHISPER Indoor Fireplace User Manual


 
UK/IRL
49
UK/IRL
48
Knob A
The { is the OFF position preventing any gas from passing through the
control valve to either the pilot burner or to the main burner. By pressing
the knob in it is possible to turn it anticlockwise. The first function is to
turn on the gas to the pilot- this occurs just before reaching the
|position (if the fire has not been lit for some time it may be necessary
to hold the knob in this position for some seconds to clear the air from
the pipe and allow gas to reach the pilot burner). Once gas is available
at the pilot, continued rotation anti-clockwise will cause the piezo igniter
to spark. This is accompanied by a click at the valve and should result in
the pilot burner igniting. Once the pilot is lit, the control knob should be
held pressed in for 10 seconds. In this time the pilot flame will have
heated the flame supervision thermocouple sufficiently to operate a hold-
on magnet within the valve. Now turn the control knob A to the
position. This allows gas to enter control knob B.
Knob B
The { is the OFF position preventing gas entering the main burner if
the pilot is lit. The knob should be turned slowly anticlockwise. This
allows gas to enter the burner and be ignited by the pilot flame. Once
ignition has taken place, the fire may be set to any level between min.
and max. by adjusting the control knob B.
10.2 To light
1. Push in and turn the control knob (A) from { anticlockwise to
the setting (small flame). You will hear a ignition click. Check
that the pilot is lit (if not repeat).
2. Continue to hold in the control knob for a further ten seconds to
ensure that the pilot flame is stable.
3. Release the knob. The pilot should remain alight.
4. Turn the control knob A to the position.
5. Turn knob B slowly anticlockwise, the fire should then ignite.
6. Adjust flames to the required level.
10. CONTROLLING THE APPLIANCE
10.1 Lighting the fire
If the main burner or pilot light are extinguished for any reason, do
not attempt to relight the pilot within 5 minutes. Contact a qualified
installer when the appliance goes off regularly.
The control valve is behind the ashtray door.
Silence /Feeling /Whisper
Open the ashtray door by pushing on the right side for the
Silence/Feeling and on the left side for the Whisper.
Misty
Open the ashtray door by pulling down (bottom handle with gas
damper).
Cadra Nova and Spectra Nova
Open by pushing the lip located on the right side in the gap between
the ashtray door and the frame (door flaps open).
With control button A you can light the pilot. With the control button
B you can adjust the height of the flames (see fig. 27).
fig. 27 control unit
A
B