Faber FEELING Indoor Fireplace User Manual


 
UK/IRL
37
UK/IRL
36
8.1.4 Burner tray assembly
1. Remove the front, glass, log set, grid and burner tray cover.
2. Break the gas supply at the control valve.
3. Unscrew the burner assembly and take them out of the combustion
chamber.
A. Pilot assembly
B. Burner
C. Fixation plate
D. Injector
E. Gas control
F. Receiver
8.1.5 Pilot/thermocouple assembly
Remove the burner tray as described above.
Now you have access to all the pilot and thermocouple parts.
fig. 25
A
B
C
D
E
F
8.1.1 Cleaning the glass
Depending on the intensity of use, you can get a deposit on the
glass. This can be removed with a special ceramic glass cleaner
(ceramic cook-top cleaner) as follows:
1. Remove the front and the back.
2. Clean the glass. Handle the glass with clean hands, wear gloves if
possible.
3. To fit the glass, proceed in reverse order. Make sure that the log
set has been installed correctly before fixing the glass.
Attention:
Before placing the glass: check the glass sealing rope is in good
condition and makes an effective seal. Be sure that there are no
fingerprints on the glass. It is not possible to remove those prints
after you burn the appliance for a while (they are burnt in). Place
the glass in front of the appliance and fix the glass frame or use the
glass clamps.
8.1.2 Cleaning the combustion chamber and burner
You can clean the combustion chamber with a vacuum cleaner.
If the burner is visibly damaged, this can affect the distribution of
the flame, if so then replace the burner.
8.1.3 Propane conversion
For conversion from propane to natural gas, order for a propane
burner unit.
Please give the serial number from the data plate when you order.