Everpure MC Water System User Manual


 
SELECTING A MOUNTING LOCATION
1. Give consideration to the weight of the unit when operating (filled with water). Operating weights
of High Flow CSR Systems are:
• TwinSystem-45lbs(20.2kg)
• TripleSystem-47lbs(21.2kg)
• QuadSystem-49lbs(22.2kg)
• QuadPlusSystem-49lbs(21.2kg)+separatesurge/storagetank@60lbs(27.2kg)
2. Thelocationshouldallowfor(Seegures1-8):
• Minimumclearanceof2
1
2"underthecartridge(s)soitcanbeloweredforremovaland
replacement.
• Adequatespacefor“in”and“out”waterlineconnections.Benearadrainforushingandnear
a110VoutletiftheoptionalEverguard
LowPressureAlarmisused.
• AdditionalmountingandoorspacefortheseparateSR-XFeederandsurge/storagetank
(Quad
Plus).
OPERATING SPECIFICATIONS*
Combined Model Name
Replacement
Cartridge
Flow Rate Capacity
HighFlowCSRTwin-MC MC 3.3gpm(12.5lpm) 18,000gal.(68,000L)
HighFlowCSRTwin-MC
2
MC
2
3.3gpm(12.5lpm) 18,000gal.(68,000L)
HighFlowCSRTwin-XC XC 3.3gpm(12.5lpm) 18,000gal.(68,000L)
HighFlowCSRTwin-XC
2
XC
2
3.3gpm(12.5lpm) 18,000gal.(68,000L)
HighFlowCSRTwin-4CB5 4CB5 3.3gpm(12.5lpm) 12,000gal.(45,400L)
HighFlowCSRTwin-7CB5 7CB5 5.0gpm(18.9lpm) 20,000gal.(75,700L)
HighFlowCSRTriple-MC MC 5.0gpm(18.9lpm) 27,000gal.(102,000L)
HighFlowCSRTriple-MC
2
MC
2
5.0gpm(18.9lpm) 27,000gal.(102,000L)
HighFlowCSRTriple-XC XC 5.0gpm(18.9lpm) 36,000gal.(136,000L)
HighFlowCSRTriple-XC
2
XC
2
5.0gpm(18.9lpm) 36,000gal.(136,000L)
HighFlowCSRTriple-4CB5 4CB5 5.0gpm(18.9lpm) 18,000gal.(68,000L)
HighFlowCSRTriple-7CB5 7CB5 7.5gpm(28.5lpm) 30,000gal.(113,550L)
HighFlowCSRQuad-MC MC 6.6gpm(25.2lpm) 36,000gal.(136,000L)
HighFlowCSRQuad-MC
2
MC
2
6.6gpm(25.2lpm) 36,000gal.(136,000L)
HighFlowCSRQuadPlus-XC XC 6.6gpm(25.2lpm) 48,000gal.(181,600L)
HighFlowCSRQuadPlus-XC
2
XC
2
6.6gpm(25.2lpm) 48,000gal.(181,600L)
*Forindividualcartridgespecications,refertocartridgeliterature.
Temperature: 35-100°F(2-38°C)
Pressure: 10-125psi(0.7-8.6bar),non-shock
For cold water use only.
INSTALLATION
1. Usethepredrilledmountingholesinthemanifoldbracketasguides.Markanddrillanchorholes.
Mountsecurely.SeeFigures5-8.
2. Shutoffpowertoequipment.IfsystemisaHighFlowCSRQuadPlus(separateSR-XFeederand
surge/storagetank
),proceedtostep3b.
3a.ConnectoutletportsofHighFlowsystemtoequipmentservedpertheinstructionsbelow.Always
useNSFapprovedpipedopeorTeontapeatallconnections.Useabackupwrenchonallttings
while connecting to avoid stress on the system components.
• ThecrossttingbeforetheSR-XFeederhasathreadedoutletontop.Connectaminimum1/2"
I.D.linefromthisoutlettofountainbeverageequipment.
• Thecrossttinghasaushingvalveinstalledonthebottom.Connecttubingtotheushingvalve
andruntodrain.Note:Somemunicipalplumbingcodesandgoodsanitarypracticesrequirean
air gap at the drain termination point.
Figure1–Twin
EV3112-78RevEAP08
Installation and Operation Guide
High Flow CSR Filter Systems
Figure2–Triple
Figure4–QuadPlus
Figure3–Quad
ManufacturedbyEverpure