Everpure CGHC-1 Instant Water System User Manual


 
product specifications
Everpure, Micro-Pure, Helia™ and the silver canister color are registered trademarks of Everpure, LLC © 2008
This water appliance is approved by Underwriters Laboratories Inc.
in accordance with NSF/ANSI 61-2002e.
Helia™
CGHC-1 Instant
Hot & Chilled Water Appliance
capacity
6.6 gallons per hour for chilled water and
2.1 gallons per hour for hot water
temperature output
40°F (based on 68°F inlet water and 77°F
ambient)
inlet/outlet
1/4” O.D. tubes for inlet and 6 mm O.D.
tubes for outlets
power
870 watts
motor compressor
1/12 HP, 115 VAC, 60Hz single phase
everpure warranty
The Helia™ appliance has a 24-month
limited warranty on the refrigeration
system of the unit. Electrical components
and water system are warranted for 12
months from date of installation. Warranty
pertains to drinking water applications
only. Non-drinking water applications are
not covered under warranty. A detailed
warranty statement is included with each
unit.
Helia™ CGHC-1 Instant Hot & Chilled
Water Appliance – Part No. EV9318-50
Features:
> True commercial grade quality, delivering up to 6.6 gallons of chilled water per hour or 2.1 gallons of
hot water per hour
> Chills to an ideal temperature of 40ºF.
> Heats to an ideal temperature of 200ºF, with adjustable temp control
> Compact unit is easy to hide in any kitchen cabinet or wet bar.
> Sealed ice bank cooling system ensures constant availability of chilled water
> Stainless steel components.
> 3 wire service cord and plug included.
> Ambient water port equipped.
> Child proof hot water selector to dispense water at predetermined level
General Installation/Operation/Maintenance Requirements:
> Measures 16” high x 10” wide x 18” deep.
> Adjustable thermostat is factory pre-set.
> Install in well-ventilated cabinet.
Helpful Tips
> Position the appliance in the point of installation, away from sources of heat and direct sunlight
> Do not install the appliance outdoors and in very damp rooms
> The appliance should be positioned in such a way as to leave approximately 2.40 to 2.80 inches of
space free for air to circulate freely
> Special ventilation grills/slits may be required when installing the unit in a cabinet so that the heat
produced by the refrigerating circuit can properly circulate and escape
> Make sure the appliance s resting fully on all four supporting feet
> Before making the water connection, make sure the incoming water pressure is between 14.5 psi
and 43.5 psi
> If the incoming water pressure is below 14.5 psi or the flow rate is less than 0.50 gpm, fit a device
capable of increasing the pressure (such as an autoclave or similar)
> If the incoming water pressure exceeds 43.5 psi, predispose a pressure reducer capable of
reducing the latter to the 14.5 psi and 43.5 psi