Euro-Pro EP922HA Carpet Cleaner User Manual


 
OPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS
Components
Power “On” Light (red): This light will
illuminate when the unit is plugged into
the 120V. wall outlet. This light will cycle
on and off with the steam ready light.
CAUTION: Read the instructions
for “Filling the Water Tank” before
opening the Safety Cap.
CAUTION: Always unplug
before filling. ALLOW UNIT TO
COOL FOR FIFTEEN (15)
MINUTES BEFORE REFILLING.
IMPORTANT: Do NOT add cleaning
solutions, scented perfumes, oils or any
other chemicals to the water used in this
appliance. Use tap water or
distilled/purified water if the tap water
in your area is very hard.
Filling or Refilling Your Steam
Cleaner With Water
IMPORTANT: Always insure that the unit
is “UNPLUGGED” from the wall receptacle
prior to initial filling or re-filling the water
tank and has been allowed to cool for 15
minutes. Never attempt to fill this unit
under a water tap, always use the filling
funnel provided.
Step 6: Connect desired attachments
onto the Flexible Steam Hose.
Step 7: Plug the unit into a standard (120
volt, grounded) wall receptacle.
Allow approximately 8-10 minutes
for vapor to reach its working
temperature and pressure. The
green ready light will illuminate
when the unit is ready for use.
Always point nozzle outlet in a safe
direction.
NOTE: When the steam cleaner has run
out of water, steam output will cease.
Remove the funnel slowly and let
the remaining water in it to go
inside the water tank. Do Not
Overfill. Replace the Safety
Filler Cap.
WARNING: Allow unit to cool for
15 minutes before refilling. When
refilling the steam cleaner while the
boiler is still hot, there is a risk that
water will squirt back during filling
and cause scalding. Extreme care
should be taken when refilling the
unit. Use caution when opening the
Safety/Filler Cap as cap may become
hot during use and escaping steam
can cause scalding.
Fig. 5
Attaching the Steam Pocket
Towel to the Frame
WARNING: Always insure the unit is
UNPLUGGED” from the wall
receptacle prior to attaching or
removing accessories.
Fig. 10
Note that the flat on the nozzle
must face toward the side of the
frame with the brass pin. Once
inserted, rotate it 90°.
Step 3: Insert the electrical power cord
into the outlet. Heating time
is approximately 8-10 minutes
with cold water. Filling the steam
generator with hot water will
shorten the heat up time.
Fig. 8
Fig. 7
Step 1: Connect one of the extension
tubes to the hand grip on the
flexible steam hose. To
attach the extension tubes
one onto the other or onto the
hand grip, press the locking
button ensuring that it fits into the
hole. (Fig. 7, Fig. 8) To
disconnect, repeat the operation
by pressing the locking button
and pulling the two sections
apart.
NOTE: Fit the steam pocket frame with
the angle adapter onto the extension tube.
Step 2: If the angle adapter is not
attached to the steam pocket
frame, attach as follows: Hold
the steam pocket frame in one
hand and the
angle adapter in the
other. Insert the
angle adapter
stem into the
opening of the
steam pocket frame as
shown in Fig. 9
Fig. 9
Using the Variable Steam
Feature
Your steam cleaner has a variable
steam feature that allows you to adjust
the steam flow to the job that you are
doing. For example, set the variable
steam at lower settings when using
the window squeegee and at higher
settings when cleaning grout seams.
The variable steam control is located
on the handgrip. Fig. 6 To increase the
steam flow, turn the knob counter
clockwise and to decrease, turn it
clockwise.
Fig. 6
Using Your Steam Cleaner with
Steam Pocket
1. Slide the steam
pocket towel over
the steam pocket
frame. (Fig. 10)
Fig.11
3. Bring the velcro strips
that are on the
back side of the
steam pocket towel
over the steam pocket
frame and attach to
the inside of the
front side of the
steam pocket towel. (Fig. 12)
Fig. 12
NOTE: If replacing the steam pocket
towel, make sure that the steam pocket
frame has been allowed to cool before
removing or attaching a new steam
pocket towel.
2. Bring the towel all
the way to the top
of the steam
pocket frame.
(Fig. 11)
Step 1: Before refilling the steam cleaner,
make sure that the unit is NOT
plugged in and has been allowed
to cool for fifteen (15) minutes.
Step 2: Plug the power cord in to an
electrical outlet and press the
steam switch on the hand grip to
the “ON” position to vent of any
residual steam that is in the boiler.
Step 3: Remove the power cord from the
electrical outlet and turn the steam
switch on the hand grip to the
“OFF” position.
Step 4: Place the unit on a flat, stable
surface. Slowly turn the safety
filler cap counter clockwise until it
is removed.
Step 5: Insert the funnel into the tank
opening and add 40 US Fl, Oz.
(1200 ml) of water. Place the
funnel in the tank opening as
illustrated in Fig. 5. The funnel has
been specially designed to show
when the water tank is full. When
water starts to come out of the
vent hole of the funnel, the tank is
full.
WARNING: Allow unit to cool
for 15 minutes before refilling.
Use caution when opening the
Safety/Filler Cap as cap may
become hot during use and
escaping steam can cause
scalding.
6
7