Eureka 5700 Vacuum Cleaner User Manual


 
12
Brush Roll Belt
Brush Roll
5. Place new belt around motor shaft.
6. Place belt around brush roll pulley.
7. Align left end cap with base. Push end cap securely
into place.
8. Pull right side of brush roll to stretch belt. Secure right
end cap into base.
IMPORTANT
9. Rotate brush roll by hand two full
rotations to properly position belt.
10. Place hood back on cleaner. Make sure hood front
is behind furniture guard. Replace three screws.
11. Tighten screws.
Use GENUINE EUREKA replacement belt, Style U.
Look for the GENUINE EUREKA product symbol.
5
1. Lower handle to floor to change belt.
2. Remove three screws indicated by screwdrivers in
above illustration. Lift hood to remove.
NOTE: The carpet height adjustment has to be in
the lowest or highest position to remove or reinstall
the hood.
Brush
Roll
Belt
Motor
Shaft
4
1
Brush Roll
The brush roll turns as it sweeps and combs the carpet nap.
Remove hair and threads from the brush roll so it continues
brushing the carpet. To maintain the most efficient cleaning,
the bristles must touch the carpet. To test the bristle length,
hold a ruler against the underneath side of the cleaner. If the
bristles no longer touch the ruler, replace the brush roll.
Brush Roll Belt, Style U
The brush roll belt turns the brush roll to agitate, sweep, and
comb the carpet nap. Check the belt regularly to be sure it is in
good condition. Replace the belt if it stretches, cracks or loses
tension. Cut away any hair or threads wound around the brush
roll or the belt pulley because the buildup could cause the belt
to rotate unevenly.
How To Replace Brush Roll Belt
NOTE: Turn off the switch and unplug the
electrical cord before replacing belt. Belt pulleys
can become hot during normal use. To prevent
injury, avoid touching the motor shaft when
changing the belt.
2
6
7
8
9
2
2
PERIODIC MAINTENANCE
3. Lift left end of brush roll.
4. Remove and discard belt.
3