Eureka 2290 Vacuum Cleaner User Manual


 
How to Check and Clear Hose Blockages
Low suction or poor pickup may be due to a blockage in the vacuum cleaner.
1. Remove attachment hose and check suction at end of hose
– if little or no suction, check disposable dust bag. Change
if needed. If no improvement proceed to step 2.
NOTE: Turn off the switch and unplug the electrical cord
before clearing hose.
2. Remove bag cover and disposable dust bag.
3. Remove tube inside dust bag compartment by removing 3
screws.
Check for any obstructions that may be in the hose. Any
obstructions can be removed by using a blunt instrument to
clear the hose. Flexing the hose may help loosen the clog.
4. Reinstall the tube after clearing any clog. Reinstall the
disposable dust bag and bag cover.
NOTE: If no improvement in performance on carpet, proceed
to following page.
2. Remove bag cover. Press down on handle latch and
lift cover away from cleaner.
1. Remove attachment hose and check
suction at end of hose.
3. Remove tube inside dust bag
compartment by removing 3 screws.
1
12
2
3
Handle
Latch