Essick Air 7D6 100 Humidifier User Manual


 
CONTROL PANEL
TO TURN ON/OFF
For initial operation, plug the unit
in (the display will show - -). Press
the speed button and hold for 5
seconds to turn the unit on or off.
FAN SPEED
The 7D6100 has a four speed
digital control panel.
1) Press the SPEED button to
adjust the fan speeds
2) The speeds: High (F4) - Low
(F1) display on the digital panel.
HUMIDITY CONTROL
3) The hygrometer on the cord reads the current room humidity and displays
the percentage on LCD panel.
4) To set the desired humidity, press the HUMIDITY button. Each successive
push increases the humidity in 5% increments. The range is 25% to 65%.
5) At 65% the humidifier will run constantly with or without water.
NOTE: If excessive condensation occurs, reduce fan to a lower speed setting.
CAUTION: Disconnect power before filling, cleaning or servicing unit.
Keep grille dry at all times.
CHECK FILTER
The ability of any humidifier to efficiently supply humidity output relies heavily on the
condition of the filter. As the filter loads with impurities it gradually loses its wicking
capability. When this happens, moisture output is reduced and the humidifier has to
work longer to satisfy the selected setting.
This humidifier has a check filter reminder timed to appear
after 720 hours of operation. When the Check Filter (CF)
message is displayed, disconnect the power cord and check
the condition of the filter. If a build-up of deposits or severe
discoloration is evident replace the filter to restore
maximum efficiency.
The CF function is reset after plugging the unit back in.
CONTROL LOCK FEATURE
To avoid unwanted tampering with the humidifier settings the
controls can be locked.
ACTIVATION PROCEDURE
After the humidifier functions have been set up, hold the
Speed and Humidity buttons down for 5 seconds. The display
will show “CL” for 2 seconds; release the power button and
the control will resume the display of the room humidity. The humidifier will
continue to function with the locked in settings. I
f buttons are operated while “CL”
is active, the
“CL” is displayed and settings are unaffected.
DEACTIVATION PROCEDURE
To deactivate the “CL” function simply press and hold both buttons for 5
seconds. “CL” will flash at the rate of 1 second on and 1 second off for a period
of 2 seconds and then resume the display of room humidity.
6