Initial Installation
QUALIFIED INSTALLERS ONLY
coRneR instaLLation:
The dimensions for installing a replace in the corner of a room are given below in Figure 11.
RaiseD FiRePLaces anD heaRths:
There are a few options with raised replaces: raised with no hearth, raised with a raised hearth, or raised
with a oor level hearth. If the replace is 3 inches (76 mm) or more above the oor, a hearth is not
required. This measurement should be taken from the top of the ooring, i.e. the top of the carpet. The
replace cannot be placed within 41 inches (1041 mm) of the ceiling. When installing a raised replace,
it is imperative that the support stand is strong enough to hold the weight of the replace and venting.
12
1
/
16
"
(307mm)
66
1
/
8
"
(1681mm)
42"
(1067mm)
20
7
/
8
"
(530mm)
14
3
/
4
"
(375mm)
19
1
/
2
"
(494mm)
46
3
/
4
"
(1189mm)
14
3
/
4
"
(375mm)
Figure 16. Dimensions for a corner installation.
Figure 17. Raised Fireplace with no Hearth
Figure 18. Raised Fireplace with Floor Level Hearth