Enviro 50-1574 Stove User Manual


 
Installation
CLEARANCES TO COMBUSTIBLES:
This unit can be installed on a combustible floor when installed with the optional hearth pad part 50-1568
(for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth
pad must be used for stability.
ALCOVE CLEARANCES:
This unit may be installed in an alcove.
Maintain these clearances to combustibles.
Minimum Alcove width 1220mm (48 inches)
Minimum Alcove height 1220mm (48 inches)
Maximum Alcove depth 1220mm (48 inches)
Install vent at clearances specified by
the vent manufacturer.
Side Wall
Back Wall
Adja
c
e
n
t
W
a
l
l
7
7
/8"
(20cm)
4"
(10cm)
4" (10cm)
48"
(122cm)
48"
(122cm)
48"
(122cm)
These dimensions are minimum clearances
but it is recommended that you ensure
sufficient room for servicing, routine cleaning
and maintenance.
Side wall to unit 200mm (7 inches)
Back wall to unit 100mm (4 inches)
Corner to unit 100mm (4 inches)
In Front of unit 800mm (31” inches)
Figure 3: Evolution Clearance to Combustibles.
Figure 4: Evolution Minimum Alcove Size.
8