Enviro 50-1385 Stove User Manual


 
Operating Instructions
OPERATING YOUR PELLET STOVE:
PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed correctly
against the ignitor tube with the large vertical lip at the front for proper operation. Check the hopper for
enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
MANUAL MODE:
To START: Press the ON / OFF button. The stove will turn on, it may take fifteen (15) seconds for the
lights on the control board to come on. The Auger Light will flash with each pulse of the auger (the Auger
Feed Rate is pre-programmed during start-up). The Heat Level Indicator will show the Heat Level that
the stove will run at after start-up and can now be set.
If this is the first time the unit has been started or the unit has run out of fuel, a handful of pellet should
be placed in the burn pot.
To OPERATE: When a fire has been established (after approximately 10 - 15 minutes) and the Auger
Light will start to flash to the corresponding Heat Level setting. The Heat Level will now be at the desired
Heat Level Output setting.
The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting
of the heat level output indicator.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different
quality fuels. These settings can be used if the fire keeps going out on low (for poor quality fuel) or if the
low setting is too hot for the room. This button is on the Motherboard behind the surround panel.
THERMOSTAT / SWITCH MODE:
INITIAL START-UP: See above
OPERATION - HI / LOW mode: When the thermostat contacts are closed the stove settings are
adjustable as per Manual Mode (see above). When the thermostat contacts open, the circuit board will
take control of the settings. The stove will drop down to a low burn until the thermostat contacts close
again. This low burn setting can be adjusted for different fuel qualities. The stove will come back to the
previous HEAT LEVEL setting when the thermostat contacts close again.
OPERATION – ON / OFF mode: When the thermostat contacts close, the unit will light automatically.
Once up to temperature, the stove operates the same as in manual mode (see above). When the
thermostat contacts open, the unit automatically begins its shutdown routine. The stove will re-light
when the thermostat contacts close again.
TURNING YOUR PELLET STOVE OFF:
MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button. This will stop
the feed of pellets. The blowers will continue to operate and cool the stove down. When cool enough,
the stove will turn off.
ON / OFF mode: To turn the unit OFF, turn the thermostat down or off.
DO NOT unplug unit while Combustion fan is operating.
This will lead to smoke escaping from the stove.
8