Enviro 50-1221 Stove User Manual


 
Installation
TYPICAL THROUGH WALL WITH EXTERIOR BLOWER KIT INSTALLATION - HORIZONTAL TERMINATION:
Electrical Cable
90° Elbow
45°Elbow with Rodent
screen or stainless
steel termination hood
2ft (610mm) Riser
Pipe Adaptor
Exterior Blower
and Housing
Wall Strap
To supply power to
the exhaust blower
Install the amour coated electrical cable from the exhaust blower housing, through the wall thimble plate
and attach to the pre drilled hole in the left hand rear hopper pillar. Hook up to wires from the exhaust
blower wiring harness.
All electrical connections must be in accordance to local code requirements
NOTE:
Ensure that all interior vent connections are sealed by placing a small bead of high temperature silicone
around each chimney connection.
Also ensure that all vertical vent sections are properly supported and that all clearances to combustibles
are maintained in accordance with the vent manufacturer’s specifications.
Figure 22: Through Wall Installation with Exterior Blower Kit.
Figure 23: Through Wall Installation with Exterior Blower Kit; Side View.