England's Stove Works 55-SHP22 Stove User Manual


 
CAUTION: Moving Parts May Cause Injury.
Do NOT Operate with Panel(s) Off.
DANGER: Parts May Be Hot. Risk of Electric Shock.
Disconnect Power Before Servicing Unit.
Illustration 2b
Control Board
Diagram
(Wiring)
Notes on termination of Pellet Vent Pipe (see also “FLUE SYSTEM” section of manual):
1. Not less than three (3) feet above any forced air inlet located within ten (10) feet.
2. Not less than four (4) feet below, four (4) feet horizontally from, or one (1) foot above any door, window or
gravity air inlet into any building.
3. Not less than two (2) feet from an adjacent building, and not less than seven (7) feet above grade where
located adjacent to public walkways.
The exhaust exit shall be arranged so that the flue gases are not directed so that it will affect people, overheat
combustible structures, or enter buildings. Forced draft systems and all parts of induced draft systems under
positive pressure during operation shall be installed gastight or to prevent leakage of combustion products into
a building. Through-the-wall vents shall not terminate over public walkways, or where condensate or vapor
could create hazards or a nuisance.
Be sure to follow local codes and all manufacturer’s instructions (including exhaust pipe). Consult a
professional installer and/or call Customer Service if you have any questions.
IMPORTANT SAFETY NOTE: If the unit or chimney connector pipe “glows” red (or
white), the stove is over-fired. This condition could cause a house or chimney fire.
Do not o
p
erate
y
our unit too hot
,
or ove
r
-firin
g
ma
y
result.