England's Stove Works 50-SFP12P Stove User Manual


 
3
CAUTION
If you have any doubt concerning your ability to complete your installation in a professional-
like manner after reading these instructions, you should obtain the services of an installer
who is versed in all aspects as to the correct and safe installation. Do not use temporary,
makeshift compromises during installation.
BEFORE INSTALLATION OF YOUR APPLIANCE
1. HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.
CONTACT MAY CAUSE SKIN BURNS.
2. DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS.
3. Check with the building inspector’s office for compliance with local codes; a permit may be
required.
4. This room heater must be connected to (1) a listed Type HT (2100°F) chimney per UL 103 or
ULC S629, or (2) a code-approved masonry chimney with a flue liner. The chimney size
should not be less than the area of the flue collar, or more than three times greater than the
cross-sectional area of the flue collar.
5. A 6” diameter flue is required for proper performance.
6. Always connect this unit to a chimney and NEVER vent to another room or inside a building.
7. DO NOT connect to any duct work to which another appliance is connected, such as a
furnace.
8. DO NOT connect this unit to a chimney flue serving another appliance.
9. DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE.
10. The connector pipe and chimney should be inspected periodically and cleaned if necessary.
11. Remember the clearance distances when you place furniture or other objects within the area.
DO NOT store wood, flammable liquids or other combustible materials too close to the unit.
12. Contact your local fire authority for information on how to handle a chimney fire. Have a
clearly understood plan to handle a chimney fire. In the event of a chimney fire, turn air control
to a closed position and CALL THE FIRE DEPARTMENT.
13. DO NOT tamper with the combustion air control beyond normal adjustment.
14. Once the required draw is obtained, operate only with doors closed; open doors slowly when
re-fueling (this will reduce or eliminate smoke from entering the room).
15. DO NOT install these units in a mobile home or trailer. These units are NOT mobile home
approved.
16. Visit our web site at www.englanderstoves.com for helpful information, frequently asked
questions, parts/accessory orders and more. Technical Support: (800) 245-6489.