Enerco MH24TS Electric Heater User Manual


 
3
Operating Instructions and Owner’s ManualMr. Heater | Gas-Fired Infra-Red Portable Heater
HOOK-UP INFORMATION
1.1 Heater model MH24T and MH24TS are packaged completely
assembled. Propane cylinders are not included with heater
models.
1.2 Remove heater assembly from carton.
1.3 Place the slots of the black collar mounting bracket assembly
onto the collar of the bulk tank (see Fig. 1)
CAUTION:
BE SURE THE LOCKING KNOB ON THE COLLAR MOUNT-
ING BRACKET ASSEMBLY IS OUTSIDE THE COLLAR ON
THE BULK TANK. Tighten the black knob against collar of
tank.
1.4 Check reflector of the heater (See Fig. 1) and the collar
mounting bracket assembly with the three #6-32x1/2 screws
and #6-32 Keps hex nuts. Be sure screws and nuts are secure
and tight.
1.5 Make sure tank valve is in “OFF” position (clockwise).
1.6 Make sure regulator knob is in “OFF” position by turning knob
clockwise to off.
1.7 Carefully screw POL nut directly into bulk tank valve finger
tight, turning counterclockwise; then with a 7/8” open end
wrench tighten the POL fitting, hard.
1.8 Always connect the heater to bulk tank in the outdoors or in a
well ventilated area. NEVER connect heater to bulk tank near
an open flame.
1.9 Use only LP-gas cylinders constructed for use with propane
only (HD-5) and marked in accordance with the specifications
for LP-gas cylinders of the U.S. Department of Transportation
(DOT Spec. 39).
1.10 Read pages 3 and 4 before lighting heater.
WARNING
Never touch heater while in operation to avoid injury.
Move heater by grasping the propane cylinder carefully.
Figure 1
MODEL MH24T
LOCKING
KNOB
LP CYLINDER
POL NUT
TIGHTEN
REGULATOR
KNOB
HOSE ASSEMBLY
REFLECTOR
MODEL MH24TS
COLLAR
MOUNTING BRACKET
TANK VALVE
SAFETY
SHUT OFF VALVE