Enerco HS180ID Electric Heater User Manual


 
3
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Indirect Fired Portable Heater
APPLIANCE DESCRIPTION
Mobile space heater with:
closed combustion chamber and gas exhaust duct (indirect-
fired models)
open combustion chamber (direct-fired models)
INSTALLATION INSTRUCTIONS
General instructions
The heater must be operated only by properly trained
personnel. The manufacturer’s instructions must be followed.
The heater must be installed and operated so that people are
not exposed to dangers deriving from exhaust gases, from the hot
air flow and in such a way that no fire risks exist.
It is forbidden to install the heater in the surroundings of
flammable materials, combustible products, or in places where
explosion risk exist.
When the heater is used in a closed room, ensure a minimum
volume of 28,300 ft³ for the HS180ID model and 53,000 ft³ for the
HS300ID model and a continuous natural air circulation through
windows and doors. For a good combustion, provide approximately
47 cfm air flow from outside.
For the use of the heater the general and special fire safety
regulations in force in all fields of applications must be followed. In
any case the following minimum safety clearances from materials
or objects in the surroundings of the heater must be ensured:
SPECIFICATIONS
MODEL # .............................. 180 ..................... 300
Thermal power (BTU/hr) ........ 181,000 ............... 289,000
Air Flow Rating (ft³/min) ....... 1475 .................... 2650
Oil Consumption (gal/hr) ....... 1.29 ..................... 2.06
Fuel Nozzle ............................. 1.00 60° H ........... 1.50 80° W
Efficiency (%) ........................ 87.1 ..................... 88.5
Noise Level at 2m (dB(A)) ...... 73 ....................... 73
Voltage (V) ............................ 110V 60Hz 1ph.... 110V 60Hz 1ph
Electrical Power (W) ............... 460 ..................... 800
Current Rating (A) ................. 7.0 ....................... 12.0
Weight (lb) ............................. 167 ...................... 267
Length (in) ............................ 55 ........................ 66
Width (in) ............................... 24 ........................ 27
Height (in).............................. 31 ........................ 37
Flue Diameter (in) .................. 6 ......................... 6
Tank Capacity (gal) ................ 14 ........................ 26
Fuel Pressure (psi) .................. 175 ...................... 175
Air Lock Setting ..................... 2 ......................... 5.5
Clearances:
Sides: 2.5 ft Air inlet: 2.5 ft
Top: 6 ft Air outlet: 12 ft
Floors and ceilings must be made of fireproof materials in the
room where the heater is operated.
The air inlet and outlet must never be blocked for any reason.
Install the heater on a flat, level floor in a steady position.
It is forbidden to connect direct-fired heaters to air ducts.
Maintenance and checks
Depending on the operational conditions, usually every year,
the heater should be checked by qualified personnel.
Prior to start-up, the user must check for any evident non-
compliance with rules of use, safety and protection.
INSTRUCTIONS FOR USE
Start-up
The heater is factory set for operation without room
thermostat.
If operation with room (remote) thermostat is desired, remove
the socket cover (Fig.1, No.1) and insert the thermostat plug into
the socket.
Fill the tank with proper fuel.
Connect the supply plug to a 110V ~ 60 Hz single phase earthed
socket. The green lamp indicates that the heater is powered.
WARNING: THE APPLIANCE MUST BE GROUNDED
1
2
3
4
Figure 1