Enerco 3500DF Electric Heater User Manual


 
3
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Direct Fired Portable Heater
TECHNICAL SPECIFICATIONS
MH3500 DF
HS 3500DF
MH 6000DF
HS 6000DF
Heat input [kBTU/h] 360 600
Air Flow [cfm] 1795 2.800
Fuel Type Diesel/Kerosene/#1-2 Fuel Oil
Heat output [kBTU/h] - -
Fuel consumption
[gal/h] 2..6 4.32
[lb/h] 18.56 30.84
Power supply
Phase 1 1
Voltage [V] 120 120
Frequency [Hz] 60 60
Electric consumption
[W] 632 1,240
[A] 6.00 11.10
Nozzle [USgal/h] 2.00-80° S 3.00-80°S
Pump pressure [psi] 174 203
Max static pressure [in WC] - -
Recommended max. temp. in the air
duct
[°F] - -
Adjustment of combustion air Flap
[in] a=0.394 a=0.866
- -
Flue diameter [in] - -
Compulsory Flue draft [in WC] - -
Tank capacity [gal] 35.6 35.6
Dimensions, L x W x H [in] 56.4x26.38x38.3 68.5x28.8x44
Net Weight [lb] 153 243
IMPORTANT
Before using the heater, read and understand all instructions and
follow them carefully. The manufacturer is not responsible for
damages to goods or persons due to improper use of units.
GENERAL RECOMMENDATIONS
heater exhausts hot air and the combustion products into
the room, while those with indirect combustion are fitted
with a flue to take the fumes away through the chimney.
Always follow local ordinances and codes when using this
heater:
Read and follow this owner’s manual before using the
heater.
content.
materials (the minimum distance must be 6 ft.).
to the heater requirements. Direct combustion heaters
should only be used in well vented areas in order to avoid
carbon monoxide poisoning.
Never block air inlet (rear) or air outlet (front).
In case of very low temperatures add kerosene to the
heating oil.
Make sure heater is always under surveillance and keep
children and animals away from it;
Before starting the heater always check free rotation of
ventilator fan.