Enerco 1000ID Electric Heater User Manual


 
3
Operating Instructions and Owner’s ManualENERCO GROUP, INC. |Indirect Fired Portable Heater
TECHNICAL SPECIFICATIONS
MH 1000ID
HS 1000ID
MH 2000ID
HS 2000ID
MH 3000ID
HS 3000ID HS 4000ID
Heat input [kBTU/h] 11 0 205 300 400
Air flow [cfm] 880 1,530 2,500 2,760
Fuel Type 
Heat output [kBTU/h] 91.9 174.9 254.4 335.6
Fuel consumption
[gal/h] 0.80 1.48 2.28 2.82
[lb/h] 5.53 10.35 15.07 20.07
Power supply
Phase 1 1 1 1
Voltage [V] 120 120 120 120
Frequency [Hz] 60 60 60 60
Electric consumption
[W] 520 785 1.240 1.440
[A] 5.76 8.30 11.40 13.20
Nozzle [USgal/h]    
Pump pressure [psi] 167
P1: 137 P1: 160 P1: 203
P2: 239 P2: 350 P2: 348
Max static pressure [in WC] 0.5 0.5 0.5 0.5
Recommended max. temp. in the air
duct
 250 250 250 250
Adjustment of combustion air flap
[in] a=0.32
 A=1.02 A=1.50 B=1.14
Flue diameter [in] 5.9 5.9 5.9 5.9
Compulsory flue draft [in WC] 0.05 0.05 0.05 0.05
Tank capacity [gal] 10.8 17.2 27.7 35.7
Dimensions, L x W x H [in] 49.3x20.0x30.5 56.5x23.2x37.60 68.5x27.6x37.7 66.3x27.6x45.6
Net Weight [lb] 94 176 264 330
IMPORTANT
Before using the heater, read and understand all instructions and
follow them carefully. The manufacturer is not responsible for
damages to goods or persons due to improper use of units.
GENERAL RECOMMENDATIONS

combustion send hot air and the combustion products into
the room, while those with indirect combustion are fitted
with a flue to take the fumes away through the chimney.
Always follow local ordinances and codes when using this
heater:

heater.

content.

materials (the minimum distance must be 6 ft.).


to the heater requirements. Direct combustion heaters
should only be used in well vented areas in order to avoid
carbon monoxide poisoning.

fumes (see “Ventilation” on page 5) and connected to an
electrical switchboard.

shall terminate in a vertical section at least two feet long
and sufficient draft shall be created to assure safe and
proper operation of the heater.


heating oil.

children and animals away from it;

ventilator fan.

distribute warm air, with respect to the max. static pressure
declared (see “TECHNICAL SPECIFICATION” sheet).
