Empire Comfort Systems VFSR-30-3 Electric Heater User Manual


 
Page 6 18954-0-0705
This is an unvented gas-fired heater. It uses air (oxygen) from the
room in which it is installed. Provisions for adequate combustion
and ventilation air must be provided.
Keep room area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
Unvented gas heaters are a supplemental zone heater. They are not
intended to be a primary heating appliance. Water vapor produced
by an unvented heater can create moisture problems in a home
when operated for extended periods of time.
During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils, films or
bonding agents. These chemicals are not harmful but may produce
annoying smoke and smells as they are burned off during the initial
operation of the appliance; possibly causing headaches or eye or
lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in period will be slight and will disappear
with continued use.
This appliance must not be used with glass doors in the closed
position. This can lead to pilot outages and severe sooting outside
the fireplace.
Do not use this room heater if any part has been under water.
Immediately call a qualified service technician to inspect the
room heater and replace any part of the control system and any
gas control which has been under water.
WARNING: This appliance is equipped for (natural or propane)
gas. Field conversion is not permitted.
Before you get started
Carefully inspect the contents for shipping damage. If any parts are
missing or damaged, immediately inform the dealer from whom
you purchased the appliance. Do not attempt to install any part of
the appliance unless you have all parts in good condition.
Make sure you have received all parts:
Check your packing list to verify that all listed parts have been
received. You should have the following:
Gas log grate/burner assembly.
Two (2) masonry anchoring screws and two (2) 10 x 1/2" black
sheet metal anchoring screws.
Plastic bag containing glowing embers (rock wool) for burner
coverage.
Plastic bag containing lava rock.
Switch log assembly - VFSR models
Remote kit - VFSV models
Millivolt controlled heater designed to be operated with optional
devices for ON/OFF functions.
Wall switch or thermostat with wire.
Hand held remote control with ON/OFF switch or
thermostat.
Handle the gas log burner assembly by the grate and legs only.
Do not pick the unit up by the burner.
Gloves are recommended when handling logs to prevent skin
irritation. Logs are fragile - Handle with care.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equip-
ment or accessories and repair and servicing of equipment shall
be performed only by a qualified agency. The term "qualified
agency" means any individual, firm, corporation, or company
that either in person or through a representative is engaged in and
is responsible for (a) the installation, testing, or replacement of
gas piping or (b) the connection, installation, testing, repair, or
servicing of equipment; that is experienced in such work; that is
familiar with all precautions required, and that has complied with
all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by
a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental
room heaters shall provide to each purchaser a copy of 527
CMR-30 upon sale of the unit.
The installation must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code, ANSI Z223.1.*
*Available from the American National Standards Institute, Inc. 11 West 42nd
St., New York, N.Y. 10018.
High Altitudes: For altitudes/elevation above 2,000 feet ratings
should be reduced at the rate of 4 percent for each 1,000 feet above
sea level. Contact the manufacturer.
BRUCE SPECIAL COPY
GENERAL INFORMATION
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM HEATERS
Water vapor is a by-product of gas combustion. An unvented room
heater produces approximately one (1) ounce (30ml) of water for
every 1,000 BTU's (.3KW's) of gas input per hour.
Unvented room heaters must be used as supplemental heat (a
room) rather than a primary heat source (an entire house). In most
supplemental heat applications, the water vapor does not create a
problem. In most applications, the water vapor enhances the low
humidity atmosphere experienced during cold weather.
The following steps will help insure that water vapor does not
become a problem.
1. Be sure the heater is sized properly for the application, including
ample combustion air and circulation air.
2. If high humidity is experienced, a dehumidifier may be used
to help lower the water vapor content of the air.
3. Do not use an unvented room heater as the primary heat source
(an entire house).